Evidence map›Paper›PMID 39022239›Full record

ArticleQuantitative imaging in medicine and surgery2024

Comparison of dual-energy computed tomography (DECT) polychromatic and monochromatic images with and without iterative metal artifact reduction algorithm in patients with dental implants.

Shiqi Huang, Yuhong Liang, Xinqun Yao, Xiangyun Qin, Changguang He, Li'an Luo, Lveqin Huang, Yaping Lv

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shiqi HuangDepartment of Radiology, Liuzhou Municipal Liutie Central Hospital, Liuzhou, China.ORCID https://orcid.org/0009-0004-1504-6009
Yuhong LiangDepartment of Radiology, Liuzhou Municipal Liutie Central Hospital, Liuzhou, China.ORCID https://orcid.org/0009-0004-3491-4764
Xinqun YaoDepartment of Radiology, Liuzhou Municipal Liutie Central Hospital, Liuzhou, China.ORCID https://orcid.org/0009-0005-7141-9364
Xiangyun QinDepartment of Radiology, Liuzhou Municipal Liutie Central Hospital, Liuzhou, China.ORCID https://orcid.org/0009-0007-3190-5848
Changguang HeDepartment of Radiology, Liuzhou Municipal Liutie Central Hospital, Liuzhou, China.ORCID https://orcid.org/0009-0006-6209-9247
Li'an LuoSiemens Healthineers Ltd., Guangzhou, China.ORCID https://orcid.org/0000-0002-0896-2875
Lveqin HuangSiemens Healthineers Ltd., Guangzhou, China.ORCID https://orcid.org/0009-0007-8094-9601
Yaping LvDepartment of Radiology, Liuzhou Municipal Liutie Central Hospital, Liuzhou, China.ORCID https://orcid.org/0000-0003-2287-7324

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dual-energy computed tomography (DECT) and iterative metal artifact reduction (iMAR) algorithms are valuable tools for reducing metal artifacts. Different parameters of these technologies and their combination can achieve different performance. This study compared various polychromatic and monochromatic images obtained via DECT with and without using iMAR algorithm to reduce artifacts in patients with dental implants. Methods: This study included 30 patients with dental implants who underwent DECT for head and neck imaging. The computed tomography (CT) image sets comprised DECT polychromatic image sets [dual-energy (DE) polychromatic] that linearly blended 100 kV and tin-filtered 140 kV images using composition ratios of -1, -0.6, -0.3, 0, and 0.6, and virtual monochromatic images (DE monochromatic) at 90, 110, 130, 150, and 170 keV. These image sets were obtained with and without using iMAR, resulting in a total of 20 image sets. For subjective analysis, metal artifacts and image quality were assessed using a 5-point Likert scale. For objective analysis, CT attenuation, standard deviation (SD), contrast-to-noise ratio (CNR) and artifact index (AI) were evaluated. In addition, subgroup analysis was performed based on implant size. Results: In the subjective evaluation, iMAR + DE polychromatic (-0.3) images exhibited the lowest metal artifact scores [median (interquartile range): 2 (2-3)]. iMAR + DE monochromatic (110 keV) images demonstrated optimal image quality scores [median (interquartile range): 2 (2-3)]. In the objective evaluation, none of the images demonstrated a significant difference in the CNR, except polychromatic images with a composition of -1 and 0.6. iMAR + DE polychromatic (0) exhibited the lowest AI [median (interquartile range): 8.7 (5.9-14.5)]. There was no significant difference between the two groups with different implant sizes for the techniques combined with iMAR (all P>0.05). Conclusion: iMAR + DE polychromatic (-0.3 and 0) and iMAR + DE monochromatic (110 keV) images exhibited better image quality and substantial metal artifact reduction (MAR) compared with the other image sets. The performance of the techniques combined with iMAR was not affected by the size of the implant.

Indexed as

artifactsComputed tomography (CT)dental implantsdual energy (DE)

Identifiers

PMID39022239
PMCPMC11250342

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.