Application of metal artifact reduction algorithm in reducing metal artifacts in post-surgery pediatric low radiation dose spine computed tomography (CT) images.

Jihang Sun, Haoyan Li, Tong Yu, Aihua Huo, Shan Hua, Zuofu Zhou, Yun Peng

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jihang Sun *Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.
Haoyan Li *Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.
Tong YuDepartment of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.
Aihua HuoDepartment of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.
Shan HuaMedical Imaging Department, Children's Hospital of Xinjiang Uygur Autonomous Region, Xinjiang Hospital of Beijing Children's Hospital, Urumqi, China.
Zuofu ZhouDepartment of Radiology, Fujian Maternity and Child Health Hospital College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fujian, China.
Yun PengDepartment of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The commonly used methods for removing metal-induced beam hardening artifacts often rely on the use of high energy photons with either high tube voltage or high energy virtual monoenergetic images in dual-energy computed tomography (CT), the radiation dose was usually relatively high in order to generate adequate signals. This retrospective study is designed to evaluate the application of a metal artifact reduction (MAR) algorithm in reducing pedicle screw metal-caused beam hardening artifacts in post-surgery pediatric low radiation dose spine CT images. Methods: Seventy-seven children (3-15 years) who had undergone a low dose CT with 140 or 100 kV were enrolled. The radiation dose was 1.40 mGy for the 3-8 years old and 2.61 mGy for 9-15 years old children. There were 116 pedicle screws evaluated. The raw data were reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) at 50% strength, ASIR-V with MAR (AV-MAR), deep learning image reconstruction (DLIR) at high strength and DLIR with MAR (DL-MAR). The image quality concerning pedicle screws was evaluated objectively in terms of the length of beam-hardening artifact (LHA) and artifact index (AI), and subjectively using a 4-point scale (4 points: best, 3 points: acceptable). Results: Both AV-MAR and DL-MAR significantly reduced metal-induced beam hardening artifacts with smaller LHA (15.76±10.12 mm, a reduction of 57.24% and 15.66±10.49 mm, a reduction of 57.40%, respectively), and AI value (62.50±33.51, a reduction of 64.65% and 61.03±32.61, a reduction of 65.01%, respectively) compared to ASIR-V and DLIR (all P<0.01), The subjective image quality scores concerning the screws were 3.37±0.49 and 3.47±0.50 with AV-MAR and DL-MAR, respectively, higher than the respective value of 1.73±0.44 and 1.76±0.43 without MAR (all P<0.01). Conclusions: MAR significantly reduces the low-density artifacts caused by metal screws in post-surgery pediatric low-dose spine CT images, across different tube voltages, radiation dose levels and reconstruction algorithms. Combining DL-MAR further improves the overall image quality under low radiation dose conditions.

Indexed as

Artifactspediatricspedicle screwtomographyX-ray computed

Identifiers

PMID39022236
PMCPMC11250295