Cone-Beam CT Images as an Indicator of QACT During Adaptive Proton Therapy of Extremity Sarcomas.
Article in International journal of particle therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Optimizing QACT Frequency in Proton Therapy: Analysis of Standard Guidelines Across Treatment Sites.International journal of particle therapy · 2025Article
- Optimizing quality assurance CT schedules during adaptive proton therapy for enhanced patient care.Journal of applied clinical medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Periodic quality assurance CTs (QACTs) are routine in proton beam therapy. In this study, we tested whether the necessity for a QACT could be determined by evaluating the change in beam path length (BPL) on daily cone-beam CT (CBCT). Patients and Methods: In this Institutional Review Board-approved study, we retrospectively analyzed 959 CBCT images from 78 patients with sarcomas treated with proton pencil-beam scanning. Plans on 17 QACTs out of a total of 243 were clinically determined to be replanned for various reasons. Daily CBCTs were retrospectively analyzed by automatic ray-tracing of each beam from the isocenter to the skin surface along the central axis. A script was developed for this purpose. Patterns of change in BPL on CBCT images were compared to those from adaptive planning using weekly QACTs. Results: Sixteen of the 17 adaptive replans showed BPL changes ≥4 mm for at least 1 of the beams on 3 consecutive CBCT sessions. Similarly, 43 of 63 nonadaptively planned patients had BPL changes <4 mm for all of the beams. A new QACT criterium of a BPL change of any beam ≥4 mm on 3 consecutive CBCT sessions resulted in a sensitivity of 94.1% and a specificity of 68.3%. Had the BPL change been used as the QACT predictor, a total of 37 QACTs would have been performed rather than 243 QACTs in clinical practice. Conclusion: The use of BPL changes on CBCT images represented a significant reduction (85%) in total QACT burden while maintaining treatment quality and accuracy. QACT can be performed only when it is needed, but not in a periodic manner. The benefits of reducing QACT frequency include reducing imaging dose and optimizing patient time and staff resources.