Evidence map›Paper›PMID 39017958›Full record

ArticleSurgical endoscopy2024

Indocyanine green fluorescence perfusion testing in robot-assisted hepatic arterial infusion pump placement.

Roderick W J J van Dorst, Britte H E A Ten Haaft, Stijn Franssen, Inne H M Borel Rinkes, Bas Groot Koerkamp, Rutger-Jan Swijnenburg, Jeroen Hagendoorn

Abstract readMulticenter Study
In one paragraph

Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Roderick W J J van DorstDepartment of Surgery, UMC Utrecht Cancer Center, University Medical Center Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands.ORCID 0009-0000-1930-7051
Britte H E A Ten HaaftDepartment of Surgery, Cancer Center Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
Stijn FranssenDepartment of Surgery, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, The Netherlands.
Inne H M Borel RinkesDepartment of Surgery, UMC Utrecht Cancer Center, University Medical Center Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands.
Bas Groot KoerkampDepartment of Surgery, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, The Netherlands.
Rutger-Jan SwijnenburgDepartment of Surgery, Cancer Center Amsterdam, Amsterdam UMC, Amsterdam, The Netherlands.
Jeroen HagendoornDepartment of Surgery, UMC Utrecht Cancer Center, University Medical Center Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands. j.hagendoorn-3@umcutrecht.nl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHepatic arterial infusion pump (HAIP) treatment is a technique used to treat liver localized malignancy with intra-arterial chemotherapy. Methylene blue is generally administered to verify hepatic perfusion and exclude inadvertent extrahepatic perfusion. The use of indocyanine green dye (ICG) combined with near-infrared (NIR) fluorescence imaging during robot-assisted HAIP placement may be an attractive alternative by providing high contrast without blue discoloration of the operative field.

methodsData was collected retrospectively from 2 centers in the Netherlands. Intraoperative perfusion of the liver segments and extrahepatic perfusion were assessed using ICG/NIR as well as methylene blue on video imaging and correlated to postoperative 99 m-Tc perfusion scintigraphy.

results13 patients underwent robot-assisted surgery for HAIP placement; median length of stay was 4 days, complications occurred in 4 patients. Hepatic perfusion showed identical patterns when ICG was compared with methylene blue. In 1 patient, additional extrahepatic perfusion was found using ICG, leading to further vessel ligation. Intraoperative ICG perfusion was concordant with 99 m-Tc perfusion scintigraphy. DISCUSSION: Liver and extrahepatic perfusion determined by ICG fluorescence imaging is concordant with blue dye perfusion and 99 m-Tc perfusion scintigraphy. Therefore, ICG fluorescence imaging is deemed a safe and reliable technique for perfusion testing during robot-assisted HAIP placement.

Indexed as

Coloring AgentsHepatic ArteryIndocyanine GreenLiver NeoplasmsRobotic Surgical ProceduresAdultAgedFemaleHumansInfusion PumpsInfusions, Intra-ArterialMaleMethylene BlueMiddle AgedOptical ImagingPerfusion ImagingColoring AgentsIndocyanine GreenMethylene BlueChemotherapyFluorescenceRobot-assisted surgery

Identifiers

PMID39017958
PMCPMC11893147

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.