Evidence map›Paper›PMID 39014445›Full record

ArticleJournal of cardiothoracic surgery2024

Analysis of risk factors for complications in echocardiography-guided percutaneous intramyocardial septal radiofrequency ablation.

Hanzhi Wang, Jifang Cheng, Qi Chen, Zhaoxia Pu, Huajun Li

Abstract read
In one paragraph

Article in Journal of cardiothoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hanzhi WangDepartment of Nursing, The Second Affiliated Hospital of Zhejiang University School of Medicine, 88 Jiefang Road, Hangzhou, 310009, China.
Jifang ChengDepartment of Nursing, The Second Affiliated Hospital of Zhejiang University School of Medicine, 88 Jiefang Road, Hangzhou, 310009, China. 2197018@zju.edu.cn.
Qi ChenDepartment of Nursing, The Second Affiliated Hospital of Zhejiang University School of Medicine, 88 Jiefang Road, Hangzhou, 310009, China.
Zhaoxia PuDepartment of Nursing, The Second Affiliated Hospital of Zhejiang University School of Medicine, 88 Jiefang Road, Hangzhou, 310009, China.
Huajun LiDepartment of Nursing, The Second Affiliated Hospital of Zhejiang University School of Medicine, 88 Jiefang Road, Hangzhou, 310009, China.

Funding

General Research Project of Zhejiang Provincial Department of Education Y202249634
6 · The paper itself

Abstract

backgroundThe feasibility of percutaneous intramyocardial septal radiofrequency ablation (PIMSRA) for the treatment of hypertrophic obstructive cardiomyopathy (HOCM) has been previously reported. However, limited investigation has been conducted regarding the complications associated with this procedure.

objectiveThis study aims to analyze the risk factors affecting the occurrence of complications during PIMSRA, such as pericardial effusion, ventricular premature beats, and interventricular septal perforation. In this study, the optimal cut-off values for these risk factors are also explored, and corresponding strategies for prevention are proposed.

methodsA total of 101 patients diagnosed with HOCM who underwent the PIMSRA procedure from 2021 to 2022 were included in this retrospective analysis. Patients were classified into subgroups with or without complications based on procedural records. Univariate and multivariate regression analyses were conducted to identify independent risk factors for complications during the PIMSRA procedure.

resultsThere were 48 patients with complications and 53 patients without complications. The heart rate at the start of the procedure and the maximum left ventricular outflow tract gradient (LVOTG) were independent risk factors related to PIMSRA complications. The optimal cut-off values for predicting complication occurrence were a heart rate > 49 bpm at the start of the procedure (OR: 3.79, 95% CI: 1.64-8.78, p = 0.002) and a maximum LVOTG > 92 mmHg (OR: 2.57, 95% CI: 1.15-5.75, p = 0.022), respectively.

conclusionsThe occurrence of PIMSRA complications is primarily associated with the heart rate at the start of the procedure and the maximum LVOTG. It is recommended to establish a comprehensive control plan to minimize the risk of complications during PIMSRA procedures.

Indexed as

Cardiomyopathy, HypertrophicEchocardiographyAgedCatheter AblationFemaleHeart SeptumHumansMaleMiddle AgedPostoperative ComplicationsRadiofrequency AblationRetrospective StudiesRisk FactorsSurgery, Computer-AssistedComplicationHypertrophic cardiomyopathyRadiofrequency ablationRisk factor

Identifiers

PMID39014445
PMCPMC11251329

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked