Analysis of arterial blood gas values when discarding different volumes of blood samples in an arterial heparin blood collector during thoracoscopic surgery.

Ping Xue, Zhirong Sun

Abstract read
In one paragraph

Article in BMC surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ping XueDepartment of Anesthesiology, Fudan university Shanghai Cancer Center, Shanghai, China.
Zhirong SunDepartment of Anesthesiology, Fudan university Shanghai Cancer Center, Shanghai, China. 2378162006@qq.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundArterial blood gas analysis (ABGA) plays a vital role in emergency and intensive care, which is affected by many factors, such as different instrumentation, temperature, and testing time. However, there are still no relevant reports on the difference in discarding different blood volumes on ABGA values.

methodsWe enrolled 54 patients who underwent thoracoscopic surgery and analysed differences in blood gas analysis results when different blood volumes were discarded from the front line of the arterial heparin blood collector. A paired t test was used to compare the results of the same patient with different volumes of blood discarded from the samples. The difference was corrected by Bonferroni correction.

resultsOur results demonstrated that the PaO2, PaCO2, and THbc were more stable in the 4th ml (PaO2 = 231.3600 ± 68.4878 mmHg, PaCO2 = 41.9232 ± 7.4490 mmHg) and 5th ml (PaO2 = 223.7600 ± 12.9895 mmHg, PaCO2 = 42.5679 ± 7.6410 mmHg) blood sample than in the 3rd ml (PaO2 = 234.1000 ± 99.7570 mmHg, PaCO2 = 40.6179 ± 7.2040 mmHg).

conclusionIt may be more appropriate to discard the first 3 ml of blood sample in the analysis of blood gas results without wasting blood samples.

Indexed as

Blood Gas AnalysisHeparinThoracoscopyAdultAgedBlood Specimen CollectionFemaleHumansMaleMiddle AgedHeparinArterial blood gasBlood samplePartial pressure of carbon dioxidePartial pressure of oxygenThoracic surgeryTotal haemoglobin