Evidence map›Paper›PMID 39014210›Full record

ArticleEye (London, England)2024

Accuracy of formulas for intraocular lens power for eyes undergoing descemet stripping automated endothelial keratoplasty and cataract surgery.

Rosa Boccia, Vincenzo Scorcia, Michele Lanza, Giuseppe Luciano, Andrea Lucisano, Sandro Sbordone, Paolo Melillo, Francesca Simonelli

Abstract readComparative Study
In one paragraph

Article in Eye (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rosa BocciaMultidisciplinary Department of Medical, Surgical and Dental Specialities, Università della Campania Luigi Vanvitelli, Napoli, Italy.
Vincenzo ScorciaDepartment of Ophthalmology, University of "Magna Graecia", Catanzaro, Italy.
Michele LanzaMultidisciplinary Department of Medical, Surgical and Dental Specialities, Università della Campania Luigi Vanvitelli, Napoli, Italy. mic.lanza@gmail.com.ORCID http://orcid.org/0000-0002-1578-7155
Giuseppe LucianoMultidisciplinary Department of Medical, Surgical and Dental Specialities, Università della Campania Luigi Vanvitelli, Napoli, Italy.
Andrea LucisanoDepartment of Ophthalmology, University of "Magna Graecia", Catanzaro, Italy.
Sandro SbordoneMultidisciplinary Department of Medical, Surgical and Dental Specialities, Università della Campania Luigi Vanvitelli, Napoli, Italy.ORCID http://orcid.org/0000-0003-0914-8653
Paolo MelilloMultidisciplinary Department of Medical, Surgical and Dental Specialities, Università della Campania Luigi Vanvitelli, Napoli, Italy.
Francesca SimonelliMultidisciplinary Department of Medical, Surgical and Dental Specialities, Università della Campania Luigi Vanvitelli, Napoli, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo compare accuracy in intraocular lens (IOL) power calculation in eyes undergoing combined cataract and Descemet stripping and automated endothelial keratoplasty (C-DSAEK) surgery of the following formulas: Barrett Universal II, EVO, Haigis, Hoffer Q, Holladay 2, Kane and SRK/T.

methods72 eyes from 72 patients (38 males, (53%)) with a mean age 68.08 ± 8.69 years (from 44 to 88 years old) underwent combined C-DSAEK were included. The IOL powers to implant were calculated with Barrett Universal II formula targeting -1 D refraction. Preoperative and postoperative data were used to obtain the median of absolute prediction errors (MAE) targeting emmetropia with every tested formula.

resultsMeans of MAE calculated were +1.45 D for Barrett Universal II, +1.37 D for EVO, +1.48 D for Haigis, +1.38 D for Hoffer Q, +1.37 D for Holladay 2, +1.39 D for Kane and +1.31 D for SRK/T. SRK/T MAE showed major significant (p < 0.01) differences compared to the other formulas. DISCUSSION: Even if tested formulas are not able to accurately target emmetropia, SRK/T seems to be able to provide closer results in eyes undergoing C-DSAEK.

Indexed as

BiometryDescemet Stripping Endothelial KeratoplastyLenses, IntraocularLens Implantation, IntraocularOptics and PhotonicsRefraction, OcularAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedPhacoemulsificationReproducibility of ResultsRetrospective Studies

Identifiers

PMID39014210
PMCPMC11544135

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.