Evidence map›Paper›PMID 39014127›Full record

ArticleWorld journal of urology2024

Protocol description and initial experience in kidney graft perfusion using infrared thermography.

M Ciappara Paniagua, B Gutierrez Hidalgo, J Gomez Rivas, E Redondo Gonzalez, I De la Parra Sanchez, I Galindo Herrero, J Martin Monterrubio, B Bañuelos Marco, D Tueti Silva, M I Galante Romo and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

M Ciappara PaniaguaUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain. ciappara.marco@gmail.com.ORCID http://orcid.org/0000-0002-4562-9115
B Gutierrez HidalgoUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
J Gomez RivasUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
E Redondo GonzalezUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
I De la Parra SanchezUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
I Galindo HerreroUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
J Martin MonterrubioUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
B Bañuelos MarcoUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
D Tueti SilvaUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
M I Galante RomoUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.
J Moreno SierraUrology Department, Hospital Universitario Clínico San Carlos, Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeProtocol description for renal perfusion study using thermographic technology and description of the thermographic and clinical behavior of the transplanted kidneys before and after unclamping.

methodsInfrared thermographic images of renal grafts are obtained before kidney reperfusion, 10 min after and just before closing the surgical wound. Thermographic data is evaluated together with the type of graft and donor, cold ischemia time, hypovascularized areas determined by the surgeon during surgical intervention, alterations in vascular flow in postoperative echo-Doppler, time at the beginning of graft function and serum creatinine monitoring during postoperative follow-up.

results17 grafts were studied. The mean temperature of the grafts before reperfusion, 10 min after and at the end of the surgery were 18.7 °C (SD 6.27), 32.36 °C (SD1.47) and 32.07 °C (SD1.78) respectively. 4 grafts presented hypoperfused areas after reperfusion. These areas presented a lower temperature compared to the well perfused parenchyma surface using thermographic images.

conclusionThe study of the usefulness and applicability of thermography can allow the development of tools that provide additional objective information on organ perfusion in real time and non-invasive manner. Our protocol and initial results can contribute to provide new evidence. Further analyses should be developed to shed light on the role of this technology.

Indexed as

Kidney TransplantationThermographyAdultAgedClinical ProtocolsCold IschemiaFemaleHumansInfrared RaysKidneyMaleMiddle AgedPerfusionReperfusionGraftInfrared radiationKidney transplantThermographyTransplantation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked