Evidence map›Paper›PMID 39014079›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2024

Repeatability and intra and interrater reproducibility of the DIPA-S eHealth© capture and analysis system for clinical assessment of scoliosis.

Isis Juliene Rodrigues Leite Navarro, Marcelle Guimarães Silva, Ingrid Cláudia Pereira Dos Santos, Cláudia Tarragô Candotti

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Isis Juliene Rodrigues Leite NavarroUniversidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil. isisjlnavarro@gmail.com.ORCID http://orcid.org/0000-0002-6158-8018
Marcelle Guimarães SilvaUniversidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil.ORCID http://orcid.org/0000-0001-6472-5199
Ingrid Cláudia Pereira Dos SantosUniversidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil.ORCID http://orcid.org/0000-0001-8241-3738
Cláudia Tarragô CandottiUniversidade Federal do Rio Grande do Sul - Grupo Biomec, Rua Felizardo, 750, bairro Jardim Botânico, Porto Alegre, Rio Grande do Sul, Brasil.ORCID http://orcid.org/0000-0002-8676-9157

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess the repeatability, intra and interrater reproducibility of the DIPA-S eHealth© system for capturing and measuring clinical variables of scoliosis, including frontal trunk imbalance (FTI), sagittal trunk imbalance (STI), and angle of trunk rotation (ATR).

methodsPatients were photographed using the DIPA-S eHealth Capture© mobile application by family members, physiotherapists, or surgeons. Three photos were taken in each position: standing in the frontal and sagittal planes and in the axial plane in forward bending position of the trunk. The photos were analyzed by three independent evaluators using the DIPA-S eHealth Analysis© software. For repeatability, each photo was analyzed twice consecutively by the three evaluators. For intrarater reproducibility, only one evaluator reanalyzed the first photo from each plane with a 5-day interval. For interrater reproducibility, the three evaluators analyzed the first photo from each plane. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were used (p < 0.05).

resultsThe sample comprised 262 images (n = 30). Repeatability was excellent for all three evaluators in all three planes (ICC 0.94 to 1.00). Intrarater reproducibility was excellent in all three planes (ICC 0.88 to 0.99). Interrater analysis was excellent for the frontal and axial planes (ICC 0.98 and 0.93), respectively. However, it was weak in the sagittal plane ICC 0.32. The SEM ranged from 0.02 to 17.6 and MDC from 0.03 to 34.6.

conclusionThe DIPA-S eHealth© Capture and Analysis system demonstrates reproducibility for use in the clinical assessment of scoliosis through teleconsultations.

Indexed as

ScoliosisTelemedicineAdolescentChildFemaleHumansMaleMobile ApplicationsObserver VariationReproducibility of ResultsPostureReproducibility of resultsScoliosisTelemedicine

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.