ArticleMagyar onkologia2024
[Application of new imaging modalities for brachytherapy of cancer patients].
Article in Magyar onkologia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the Radiotherapy Centre of the National Institute of Oncology, Budapest, a 0.55 T MR scanner (MAGNETOM Free. Max) and a ring-like X-ray machine (ImagingRing) have been in operation since 2022. The MR scanner has a tunnel diameter of 80 cm, the X-ray machine has a ring diameter of 121 cm. The latter can also be used for cone-beam CT (CBCT) imaging. The MR scanner is mainly used for planning gynaecological brachytherapy (BT) treatments. Image distortions in MR imaging were investigated with a special grid phantom. After head and neck and breast implant, image quality of ImagingRing CBCT and planning CT was compared. The position of the radiation source was verified by radiographs taken during treatment. Despite the lower field strength, the image quality of the MR scanner was found to be adequate for treatment planning of gynaecological BT. Image distortions were found to be clinically negligible. On CBCT images obtained with ImagingRing, catheters could always be well identified, and anatomical organs were adequately visualized for head and neck treatments, but not for breast implants. The MR scanner is suitable for treatment planning for gynaecological BT due to its good image quality and low image distortion. The image quality of the ImagingRing is suitable for treatment planning for small body sizes, but not for larger sizes. The device can be used to in vivo check of the radiation source position during treatment.