Evidence map›Paper›PMID 39011514›Full record

ArticleDEN open2025

Prophylactic effect of compression stockings for elevated D-dimer levels following endoscopic submucosal dissection.

Fumito Harada, Shinya Kodashima, Ken Ikusaka, Naoaki Aoki, Yuki Shimizu, Taku Honda, Miyoko Sakurai, Kyohei Maruyama, Hitoshi Aoyagi, Akari Isono and 6 more

Abstract read
In one paragraph

Article in DEN open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Fumito HaradaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Shinya KodashimaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.ORCID https://orcid.org/0009-0007-0903-6279
Ken IkusakaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Naoaki AokiDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Yuki ShimizuDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Taku HondaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Miyoko SakuraiDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Kyohei MaruyamaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Hitoshi AoyagiDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Akari IsonoDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Ryo MiuraDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Koichiro AbeDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Toshihiko ArizumiDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Yoshinari AsaokaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Takatsugu YamamotoDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.
Atsushi TanakaDepartment of Medicine Teikyo University School of Medicine Tokyo Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: A relationship between endoscopic submucosal dissection (ESD) and deep vein thrombosis has been recognized. We previously reported that a high corrected midazolam dose (total midazolam dose/initial dose of midazolam used to induce sedation) is related to elevated D-dimer levels after ESD. In this study, the effect of compression stockings (CSs) in preventing thrombosis following ESD under sedation was evaluated by measuring D-dimer levels before and after ESD. Methods: The participants were patients who underwent ESD for upper gastrointestinal tumors during the period between April 2018 and October 2022. Patients with pre-ESD D-dimer levels ≥1.6 µg/m and patients with corrected midazolam doses ≤3.0 were excluded. A retrospective investigation of the relationship between CS use and high post-ESD D-dimer levels (difference in D-dimer levels ≥1.0 µg/mL between before and after ESD) was conducted. Results: There were 27 patients in the non-CS group (NCS) and 33 patients in the CS group. The number of patients with high post-ESD D-dimer levels was 13 (48.2%) in the non-CS group and six (18.2%) in the CS group; the number in the CS group was significantly lower ( Conclusion: Wearing CSs was related to a lower risk of high post-ESD D-dimer levels. This result suggests that thrombus formation is a cause of elevated D-dimer levels after ESD.

Indexed as

compression stockingsD‐dimerdeep‐vein thrombosisendoscopic submucosal dissectionsedative

Identifiers

PMID39011514
PMCPMC11248715

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked