Utility of an Externalized Temporary Transvenous Implantable Cardioverter-defibrillator System in the Setting of Ventricular Tachycardia Storm and Concurrent Device Infection Requiring Extraction.

Ronuk M Modi, Marianna Lozano Cruz Marquez, Shu Yang, Robert N D'Angelo, Timothy R Maher, Bahij Kreidieh, Nicholas O Palmeri, Hans F Stabenau, Dana Goldense, Emily Wacks and 5 more

Abstract readCase Reports
In one paragraph

Article in The Journal of innovations in cardiac rhythm management, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Ronuk M ModiDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Marianna Lozano Cruz MarquezPontificia Universidade Catolica de Sao Paolo, Sao Paolo, Brazil.
Shu YangDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Robert N D'AngeloDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Timothy R MaherDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Bahij KreidiehDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Nicholas O PalmeriSouth Denver Cardiology, Littleton, CO, USA.
Hans F StabenauDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Dana GoldenseDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Emily WacksDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Patricia TungDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Andre d'AvilaDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Jonathan WaksDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Peter ZimetbaumDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Andrew H LockeDivision of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.

Indexed as

Anti-tachycardia pacingcardiac implantable electronic device infectionexternalized pulse generatorimplantable cardioverter-defibrillatormonomorphic ventricular tachycardia

Identifiers

PMID39011464
PMCPMC11238887

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.