Evidence map›Paper›PMID 39010228›Full record

ArticleCritical care (London, England)2024

Absolute values of regional ventilation-perfusion mismatch in patients with ARDS monitored by electrical impedance tomography and the role of dead space and shunt compensation.

Marco Leali, Ines Marongiu, Elena Spinelli, Valentina Chiavieri, Joaquin Perez, Mauro Panigada, Giacomo Grasselli, Tommaso Mauri

Abstract read
In one paragraph

Article in Critical care (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Review
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Marco LealiDepartment of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
Ines MarongiuDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Elena SpinelliDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Valentina ChiavieriDepartment of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
Joaquin PerezDepartment of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
Mauro PanigadaDepartment of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
Giacomo Grasselli *Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
Tommaso Mauri *Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy. tommaso.mauri@unimi.it.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAssessment of regional ventilation/perfusion (V'/Q) mismatch using electrical impedance tomography (EIT) represents a promising advancement for personalized management of the acute respiratory distress syndrome (ARDS). However, accuracy is still hindered by the need for invasive monitoring to calibrate ventilation and perfusion. Here, we propose a non-invasive correction that uses only EIT data and characterized patients with more pronounced compensation of V'/Q mismatch.

methodsWe enrolled twenty-one ARDS patients on controlled mechanical ventilation. Cardiac output was measured invasively, and ventilation and perfusion were assessed by EIT. Relative V'/Q maps by EIT were calibrated to absolute values using the minute ventilation to invasive cardiac output (MV/CO) ratio (V'/Q-ABS), left unadjusted (V'/Q-REL), or corrected by MV/CO ratio derived from EIT data (V'/Q-CORR). The ratio between ventilation to dependent regions and perfusion reaching shunted units (

resultsOur calibration factor correlated with invasive MV/CO (r = 0.65, p < 0.001), showed good accuracy and no apparent bias. Compared to V'/Q-ABS, V'/Q-REL maps overestimated ventilation (p = 0.013) and perfusion (p = 0.002) to low V'/Q units and underestimated ventilation (p = 0.011) and perfusion (p = 0.008) to high V'/Q units. The heterogeneity of ventilation and perfusion reaching different V'/Q compartments was underestimated. V'/Q-CORR maps eliminated all these differences with V'/Q-ABS (p > 0.05). Higher

conclusionsRegional V'/Q maps calibrated with a non-invasive EIT-only method closely approximate the ones obtained with invasive monitoring. Higher efficiency of shunt compensation improves oxygenation while compensation of dead space is less needed at lower airway pressure. Patients with more effective compensation mechanisms could have better outcomes.

Indexed as

Electric ImpedanceRespiratory Distress SyndromeTomographyVentilation-Perfusion RatioAdultAgedCardiac OutputFemaleHumansMaleMiddle AgedMonitoring, PhysiologicRespiration, ArtificialRespiratory Dead SpaceARDSCalibrationCompensationDead spaceEITElectrical impedance tomographyNon-invasiveShuntVentilation/perfusionV′/Q

Identifiers

PMID39010228
PMCPMC11251389

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.