Evidence map›Paper›PMID 39008077›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Comparison of the use of biocompatible materials and titanium in the treatment of midshaft clavicle fractures with a patient-specific plate: a finite element analysis study.

Ahmet Yurteri, Numan Mercan, Levent Uğur

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Ahmet YurteriDepartment of Orthopaedics and Traumatology, Konya City Hospital, Konya, 42020, Türkiye.ORCID http://orcid.org/0000-0001-5242-0275
Numan MercanDepartment of Orthopaedics and Traumatology, Kahramanmaraş Necip Fazıl City Hospital, Kahramanmaraş, 46050, Türkiye. numanmercan@gmail.com.ORCID http://orcid.org/0000-0002-0581-7023
Levent UğurMechanical Engineering Department, Amasya University, Amasya, 05100, Türkiye.ORCID http://orcid.org/0000-0003-3447-3191

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundClavicular midshaft fractures treated with titanium plates may encounter complications like implant failure. We assess if alternative biocompatible materials suchs as PLA, PLA/HA, PEEK offer comparable stability. Our study evaluates the biomechanical performance of these materials in surgical management of midshaft clavicle fractures.

methodsWe simulated a personalized fixation implant with four different materials and conducted finite element analysis in ANSYS to assess maximum von Mises stress (MvMs).

resultsThe MvMs occurring on the plates, screws, clavicle, and fracture site were recorded. MvMs on titanium material at the 6th hole level (764.79 MPa) and the 6th screw level (503.38 MPa), with the highest stresses observed at 48.52 MPa on the lateral clavicle at the 1st hole level and 182.27 MPa on the medial clavicle at the 6th hole level. In PLA material analyses, the highest MvMs were observed at the 3rd hole level (340.6 MPa) and the 3rd screw level (157.83 MPa), with peak stresses at 379.63 MPa on the lateral clavicle fracture line and 505.44 MPa on the medial clavicle fracture line. In PLA/HA material analyses, the highest MvMs were at the 3rd hole (295.99 MPa) and 3rd screw (128.27 MPa), with peak stresses at 220.33 MPa on the lateral clavicle and 229.63 MPa on the medial clavicle fracture line. In PEEK material analyses, the highest MvMs were at the 3rd hole (234.74 MPa) and 6th screw (114.48 MPa), with peak stresses at 184.36 MPa on the lateral clavicle and 180.1 MPa on the medial clavicle.

conclusionOur findings indicate that titanium material shows significantly higher stresses on plates and screws compared to those on the clavicle, suggesting a risk of implant failure. PLA and PLA/HA were inadequate for fixation. Although stress on the plate with PEEK material is higher than on the clavicle, it remains lower than titanium, indicating potential stability at fracture site. Further research is needed to confirm these findings.

Indexed as

Biocompatible MaterialsBone PlatesClavicleFinite Element AnalysisFracture Fixation, InternalFractures, BoneTitaniumBenzophenonesBiomechanical PhenomenaBone ScrewsDurapatiteHumansKetonesMaterials TestingPolyestersPolyethylene GlycolsBenzophenonesBiocompatible MaterialsDurapatiteKetonesPolyesterspolyetheretherketonePolyethylene Glycolspoly(lactide)PolymersTitaniumFinite element analysisMidshaftPEEKPLAPLA/HATitanium

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.