ReviewHeart international2024
A Comprehensive Evaluation of the NAVITOR Transcatheter Aortic Valve Replacement System.
Review in Heart international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Comparison of the Self-Expandable Intra-Annular Navitor Prosthesis with the Balloon-Expandable, Intra-Annular Sapien 3 Prosthesis: A Propensity-Matched Analysis.Journal of clinical medicine · 2026Article
- Review
- Pacemaker Implantation Rates With the Self-Expandable Navitor Valve.Journal of the American Heart Association · 2026Article
- Lessons Learned From the ACURATE IDE Trial for Transcatheter Aortic Valve Replacement.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025Review
- A Comparison of Short-Term Clinical Outcomes Between the Navitor and Evolut Transcatheter Aortic Valve Prostheses.Journal of clinical medicine · 2025Article
- The Next Chapter in TAVR: Innovations and the Road Ahead.Journal of clinical medicine · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Transcatheter aortic valve replacement (TAVR) has undergone significant advancements in the last two decades, expanding its indications and refining transcatheter heart valve (THV) and delivery system designs to improve procedural success and patient outcomes. This review focuses on the Navitor™ valve, a third-generation intra-annular Portico™ valve (Abbott Structural Heart, St Paul, MN, USA) designed to address TAVR complications, particularly paravalvular leak (PVL). We present an overview of the Navitor™ system, comparing it to the first-generation Portico™ THV in terms of THV design, key iterations and clinical outcomes. The Navitor™ THV introduces two key refinements-a protective outer sealing skirt and a more flexible delivery system. These enhancements have led to a significant reduction in 30 day PVL rates, from 6.3% with the first-generation Portico™ to 0% with the Navitor™ system. Additionally, the Navitor™ system exhibited lower rates of severe bleeding (27.3% versus 13.1%) and major vascular complications (5.8% versus 0.7%) compared with the first-generation Portico™. The Navitor™ valve represents a promising advancement in TAVR technology, with notable reductions in complications such as PVL, severe bleeding, and major vascular issues, compared with its predecessor. While further research is needed to assess long-term durability, these results underscore its potential benefits in enhancing patient outcomes and reducing complications. This review provides insights into the evolving landscape of TAVR technology and its quantifiable impact on patient care.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials