Acoustic noise reduction in the NexGen 7 T scanner.

Nicolas Boulant, Samantha Ma, Erica Walker, Alexander Beckett, An T Vu, Shajan Gunamony, David A Feinberg

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Magnetic resonance imaging.Science advances · 2026
    Review
  4. Article
  5. Article
  6. Engineering clinical translation of OGSE diffusion MRI.Magnetic resonance in medicine · 2025
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nicolas BoulantCEA, CNRS, BAOBAB, NeuroSpin, University of Paris-Saclay, Gif sur Yvette, France.ORCID 0000-0003-2144-2484
Samantha MaSiemens Healthcare, Malvern, Pennsylvania, USA.
Erica WalkerBrain Imaging Center, Helen Wills Neuroscience Institute, University of California, Berkeley, California, USA.
Alexander BeckettBrain Imaging Center, Helen Wills Neuroscience Institute, University of California, Berkeley, California, USA.
An T VuUniversity of California, San Francisco, California, USA.
Shajan GunamonyImaging Centre of Excellence, University of Glasgow, Glasgow, United Kingdom.ORCID 0000-0002-3146-6079
David A FeinbergBrain Imaging Center, Helen Wills Neuroscience Institute, University of California, Berkeley, California, USA.

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
NexGen 7T MRI scanner for mesoscale brain imaging: Integration and DisseminationU24NS129949 · NINDS · UNIVERSITY OF CALIFORNIA BERKELEY · PI Alexander Beckett, David Alan Feinberg · 2023 to 2026
$5.3M
Highly Efficient MRI Pulse Sequences for High Resolution Physiological and Functional Brain ImagingR44MH129278 · NIMH · ADVANCED MRI TECHNOLOGY, LLC · PI BECKETT, ALEXANDER, FEINBERG, DAVID ALAN · 2021 to 2023
$4.3M
European Union 885876NIBIB NIH HHS U01 EB025162NIMH NIH HHS R44 MH129278NINDS NIH HHS U24 NS129949
6 · The paper itself

Abstract

purposeDriven by the Lorentz force, acoustic noise may arguably be the next physiological challenge associated with ultra-high field MRI scanners and powerful gradient coils. This work consisted of isolating and mitigating the main sound pathway in the NexGen 7 T scanner equipped with the investigational Impulse head gradient coil.

methodsSound pressure level (SPL) measurements were performed with and without the RF coil to assess its acoustic impact. Vibration measurements were carried out on the gradient coil, the RF coil, and on the patient table to distinguish the different vibration mechanisms and pathways. Vibrations of the RF coil were modified by either making contact with the patient bore liner with padding material or by changing directly the RF shield with phosphor bronze mesh material.

resultsSPL and vibration measurements demonstrated that eddy-currents induced in the RF shield were the primary cause of acoustic noise. Replacing the conventional solid copper shield with phosphor bronze mesh material altered the vibrations of the RF shield and decreased SPL by 6 to 8 dB at the highest frequencies in EPI, depending on the gradient axis, while boosting the transmit B

conclusionThis study demonstrates the potential importance of eddy-current induced vibrations in the RF coil in terms of acoustic noise and opens new horizons for mitigation measures.

Indexed as

AcousticsEquipment DesignMagnetic Resonance ImagingNoiseVibrationHumansPhantoms, Imagingacoustic noise eddy‐currents RF shield vibrations