Evidence map›Paper›PMID 39004444›Full record

ArticleBMJ military health2025

Day-to-day reliability of basal heart rate and short-term and ultra short-term heart rate variability assessment by the Equivital eq02+ LifeMonitor in US Army soldiers.

Christopher L Chapman, E A Schafer, A W Potter, E M Lavoie, B M Roberts, J W Castellani, K E Friedl, D P Looney

Abstract read
In one paragraph

Article in BMJ military health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Christopher L ChapmanUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA.ORCID http://orcid.org/0000-0001-8251-9356
E A SchaferUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA.
A W PotterUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA adam.w.potter.civ@health.mil.ORCID http://orcid.org/0000-0003-4980-8353
E M LavoieDepartment of Exercise and Nutrition Sciences, University at Buffalo, Buffalo, New York, USA.
B M RobertsUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA.
J W CastellaniUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA.
K E FriedlUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA.
D P LooneyUS Army Research Institute of Environmental Medicine, Natick, Massachusetts, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe present study determined the (1) day-to-day reliability of basal heart rate (HR) and HR variability (HRV) measured by the Equivital eq02+ LifeMonitor and (2) agreement of ultra short-term HRV compared with short-term HRV.

methodsTwenty-three active-duty US Army Soldiers (5 females, 18 males) completed two experimental visits separated by >48 hours with restrictions consistent with basal monitoring (eg, exercise, dietary), with measurements after supine rest at minutes 20-21 (ultra short-term) and minutes 20-25 (short-term). HRV was assessed as the SD of R-R intervals (SDNN) and the square root of the mean squared differences between consecutive R-R intervals (RMSSD).

resultsThe day-to-day reliability (intraclass correlation coefficient (ICC)) using linear-mixed model approach was good for HR (0.849, 95% CI: 0.689 to 0.933) and RMSSD (ICC: 0.823, 95% CI: 0.623 to 0.920). SDNN had moderate day-to-day reliability with greater variation (ICC: 0.689, 95% CI: 0.428 to 0.858). The reliability of RMSSD was slightly improved when considering the effect of respiration (ICC: 0.821, 95% CI: 0.672 to 0.944). There was no bias for HR measured for 1 min versus 5 min (p=0.511). For 1 min measurements versus 5 min, there was a very modest mean bias of -4 ms for SDNN and -1 ms for RMSSD (p≤0.023).

conclusionWhen preceded by a 20 min stabilisation period using restrictions consistent with basal monitoring and measuring respiration, military personnel can rely on the eq02+ for basal HR and RMSSD monitoring but should be more cautious using SDNN. These data also support using ultra short-term measurements when following these procedures.

Indexed as

Heart RateMilitary PersonnelAdultFemaleHumansMaleReproducibility of ResultsTime FactorsUnited Statescardiologyphysiologysports medicine

Identifiers

PMID39004444
PMCPMC12772596

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.