ArticleSensors (Basel, Switzerland)2024
A Region-Monitoring-Type Slitless Imaging Spectrometer.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In modern scientific practice, it is necessary to consistently observe predetermined zones, with the expectation of detecting and identifying emerging targets or events inside such areas. This research presents an innovative imaging spectrometer system for the continuous monitoring of specific areas. This study begins by providing detailed information on the features and optical structure of the constructed instrument. This is then followed by simulations using optical design tools. The device has an F-number of 5, a focal length of 100 mm, a field of view of 3 × 7, and a wavelength range spanning from 400 nm to 600 nm. The optical path diagram demonstrates that the system's dispersion and imaging pictures can be distinguished, hence fulfilling the system's specifications. Furthermore, the utilization of a Modulation Transfer Function (MTF) graph has substantiated that the image quality indeed satisfies the specified criteria. To evaluate the instrument's performance in the spectrum observation of fixed regions, a region-monitoring-type slitless imaging spectrometer was built. The equipment has the capability to identify a specific region and rapidly capture the spectra of objects or events that are present inside that region. The spectral data were collected effectively by the implementation of image processing techniques on the captured photos. The correlation coefficient between these data and the reference data was 0.9226, showing that the device successfully measured the target's spectrum. Therefore, the instrument that was created successfully demonstrated its ability to capture images of the observed areas and collect spectral data from the targets located within those regions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.