Evidence map›Paper›PMID 38998405›Full record

ArticleMaterials (Basel, Switzerland)2024

Design and Dynamic In Vivo Validation of a Multi-Channel Stretchable Liquid Metal Coil Array.

Elizaveta Motovilova, Terry Ching, Jana Vincent, Ek Tsoon Tan, Victor Taracila, Fraser Robb, Michinao Hashimoto, Darryl B Sneag, Simone Angela Winkler

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Elizaveta MotovilovaDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
Terry ChingPillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.ORCID 0000-0002-5747-2020
Jana VincentGE Healthcare, Aurora, OH 44202, USA.
Ek Tsoon TanDepartment of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.ORCID 0000-0003-2847-9378
Victor TaracilaGE Healthcare, Aurora, OH 44202, USA.
Fraser RobbGE Healthcare, Aurora, OH 44202, USA.
Michinao HashimotoPillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.ORCID 0000-0002-9684-2354
Darryl B SneagDepartment of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.
Simone Angela WinklerDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.

Funding

NIH HHS R00-EB024341NIH HHS R01-EB031820
6 · The paper itself

Abstract

Recent developments in the field of radiofrequency (RF) coils for magnetic resonance imaging (MRI) offer flexible and patient-friendly solutions. Previously, we demonstrated a proof-of-concept single-element stretchable coil design based on liquid metal and a self-tuning smart geometry. In this work, we numerically analyze and experimentally study a multi-channel stretchable coil array and demonstrate its application in dynamic knee imaging. We also compare our flexible coil array to a commonly used commercial rigid coil array. Our numerical analysis shows that the proposed coil array maintains its resonance frequency (<1% variation) and sensitivity (<6%) at various stretching configurations from 0% to 30%. We experimentally demonstrate that the signal-to-noise ratio (SNR) of the acquired MRI images is improved by up to four times with the stretchable coil array due to its conformal and therefore tight-fitting nature. This stretchable array allows for dynamic knee imaging at different flexion angles, infeasible with traditional, rigid coil arrays. These findings are significant as they address the limitations of current rigid coil technology, offering a solution that enhances patient comfort and image quality, particularly in applications requiring dynamic imaging.

Indexed as

liquid metalMRIRF coilstretchable

Identifiers

PMID38998405
PMCPMC11243347

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.