Evidence map›Paper›PMID 38997337›Full record

ArticleScientific reports2024

Multiplex LAMP assay for detecting the prevalent species of dust mites Dermatophagoides farinae and Dermatophagoides pteronyssinus in the domestic environment.

Yujun Shuai, Qiqi Xue, Huanxin Tu, Junjie Guo, Qiao Teng, Yueye Xu, Jingang Xu, Yuanyuan Li, Hongming Zhou, Jinhong Zhao

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yujun Shuai *Department of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China.
Qiqi Xue *Department of Laboratory Medicine, Third Affiliated Hospital of Naval Medical University, Shanghai, 200438, China.
Huanxin TuDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China.
Junjie GuoDepartment of Medical Parasitology, Qiqihaer Medical College, Qiqihaer, 161000, Heilongjiang, China.
Qiao TengDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China.
Yueye XuDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China.
Jingang XuDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China.
Yuanyuan LiDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China.
Hongming ZhouDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China. 20100039@wnmc.edu.cn.
Jinhong ZhaoDepartment of Medical Parasitology, Wannan Medical College, Wuhu, 241002, Anhui, China. zhaojh@wnmc.edu.cn.

Funding

the Academic Aid Program for Top-notch Talents in Provincial Universities gxbjZD2020071Wuhu Key Research and Development Program of China 2021yf391Young and Middle-aged Research Fund of Wannan Medical College WK202216
6 · The paper itself

Abstract

Dermatophagoides farina (D. farinae) and Dermatophagoides pteronyssinus (D. pteronyssinus) are the prevalent kinds of house dust mites (HDMs). HDMs are common inhalant allergens that cause a range of allergic diseases, such as rhinitis, atopic dermatitis, and asthma. The epidemiology of these diseases is associated with exposure to mites. Therefore, in the present study, a method named multiplex loop-mediated isothermal amplification (LAMP) was developed to detect environmental dust mites. The multiplex LAMP assay allows amplification within a single tube and has an ITS plasmid detection limit as low as 40 fg/µL for both single dust mites and mixed dust mites (D. pteronyssinus and D. farinae), which is up to ten times more sensitive than classical PCR techniques. Furthermore, the multiplex LAMP method was applied to samples of single dust mites and clinical dust to confirm its validity. The multiplex LAMP assay exhibited higher sensitivity, simpler instrumentation, and visualization of test results, indicating that this method could be used as an alternative to traditional techniques for the detection of HDMs.

Indexed as

Dermatophagoides farinaeDermatophagoides pteronyssinusNucleic Acid Amplification TechniquesAnimalsMolecular Diagnostic TechniquesSensitivity and SpecificityDermatophagoides farinaeDermatophagoides pteronyssinusHouse dust mitesMultiplex LAMP assayPCRVisual detection

Identifiers

PMID38997337
PMCPMC11245516

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.