Evidence map›Paper›PMID 38996791›Full record

ArticleInternational journal of surgery case reports2024

Subcostal wire migration from the left clavicle internal fixation: A case report.

Meirizal, Muhammad Fadhil Wasi Pradipta, Agung Susilo Lo, A Faiz Huwaidi

Abstract readCase Reports
In one paragraph

Article in International journal of surgery case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Non-intubated video-assisted thoracic surgery removal of migrated wire to the spinal canal.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2025
    Article
  3. Medial Femoral Condyle Flap as Salvage for Osteomyelitic Clavicle Nonunion.Plastic and reconstructive surgery. Global open · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

MeirizalDepartment of Orthopedics and Traumatology, RSUP Dr. Sardjito Hospital, Jl. Kesehatan Sendowo No.1, Sleman 55281, D.I.Yogyakarta, Indonesia; Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Jl. Farmako, Sendowo, Sekip Utara, Sleman 55281, D.I.Yogyakarta, Indonesia. Electronic address: meirizal426@gmail.com.
Muhammad Fadhil Wasi PradiptaDepartment of Orthopedics and Traumatology, RSUP Dr. Sardjito Hospital, Jl. Kesehatan Sendowo No.1, Sleman 55281, D.I.Yogyakarta, Indonesia; Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Jl. Farmako, Sendowo, Sekip Utara, Sleman 55281, D.I.Yogyakarta, Indonesia.
Agung Susilo LoFaculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Jl. Farmako, Sendowo, Sekip Utara, Sleman 55281, D.I.Yogyakarta, Indonesia.
A Faiz HuwaidiFaculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Jl. Farmako, Sendowo, Sekip Utara, Sleman 55281, D.I.Yogyakarta, Indonesia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundKirschner wire is a widely used implant in orthopedics, with migration being a typical problem following internal fixation. Subcostal wire migration might result in catastrophic problems such as penetration of the heart, lungs, trachea, big blood vessels, or abdominal cavity. Every orthopedic surgeon must be vigilant and mindful of the potential hazards of wire migration. CASE REPORT: a 45-year-old Indonesian male was referred from another hospital. 1 year prior, the patient underwent internal fixation of the left clavicle. 2 weeks before admission, the patient complained of stabbing pain in the left shoulder area. An X-ray examination revealed a broken end wire in the left infraclavicular area. Immediate wire-extraction surgery was planned. An X-ray and CT scan showed that the wire had migrated into the left lateral side of the 9th subcostal space and was heading inferiorly. The Thoracic and Cardiovascular Surgery Department carried out the wire evacuation. The wire was successfully removed without any concern. DISCUSSION: Previous studies have suggested that wire migration can occur due to muscular activity, respiratory motion, gravity, and upper-extremity movement. Wire migration is a condition that can occur following shoulder fixation, especially in comminuted fractures that typically use K-wires to stabilize the fragments. Upon the detection of wire migration, prompt evacuation should be conducted to mitigate the severity.

conclusionIn cases of wire migration, orthopedic surgeons should pay special attention. Actions that can be taken to prevent wire migration are to: bend the wire, use a threaded wire, and remove it quickly after callus formation.

Indexed as

Clavicle fractureKirschner wireMigration of K-wire

Identifiers

PMID38996791
PMCPMC11296238

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.