ArticleAnalytical chemistry2024
Accurate Collisional Cross Section Measurement by Multipass Cyclic Ion Mobility Spectrometry.
Article in Analytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Identification of Glycosylated and Prenylated (Iso)flavonoids Using cIMS-MS.Analytical chemistry · 2026Article
- Characterization of Gas-Phase Native(-like) Proteins Using Structures for Lossless Ion Manipulations.Analytical chemistry · 2026Article
- Spatial Mapping of Stereoisomeric and Isobaric Alkaloids inAnalytical chemistry · 2025Article
- Development and Modification of Ion Mobility Mass Spectrometry Instrumentation for Enhanced Analysis of Biological Molecules.Journal of the American Society for Mass Spectrometry · 2025Review
- Multipass CCS Refiner: A Web Application for Accurate Collision Cross Section Calibration in Cyclic Ion Mobility-Mass Spectrometry.Journal of the American Society for Mass Spectrometry · 2025Article
- A Spatial Metabolomics Annotation Workflow Leveraging Cyclic Ion Mobility and Machine Learning-Predicted Collision Cross Sections.Journal of the American Society for Mass Spectrometry · 2025Article
- Multi-Pass Arrival Time Correction in Cyclic Ion Mobility Mass Spectrometry for Imaging and Shotgun Lipidomics.ACS measurement science au · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Ion mobility-mass spectrometry (IM-MS) is a powerful analytical tool for structural characterization. IM measurement provides collision cross section (CCS) values that facilitate analyte identification. While CCS values can be directly calculated from mobility measurements obtained using drift tube ion mobility spectrometry (DT-IMS), this method has limited mobility resolution due to the practical constraints on the length of the ion drift path. Consequently, DT-IMS cannot differentiate analytes with similar mobilities or resolve fine mobility features of individual ions. Cyclic IMS (cIMS) instruments leverage a cyclic path enabled by traveling wave ion mobility (TWIM) technology and offer increased mobility solution to address this challenge. While TWIM devices must first be calibrated to enable CCS measurements, current calibration strategies are primarily tailored for single-pass analyses. This preference is partly attributed to the challenges associated with multipass calibration methods, which require both calibrants and analytes to experience the same number of passes. Achieving this consistency can be complicated due to factors like peak splitting and diffusion, and may not be feasible for online IM-MS analyses. A recent report employed average ion velocities obtained from multiple measurements under different separation pathlengths as a path length-independent metric for CCS calibration. However, the ability to exploit this averaging approach is limited by observed variation in ion drift time/velocity in these measurements. In this study, we introduce a novel calibration strategy designed for multipass cIMS analyses, directly targeting the root cause for the path length- and mobility-dependent variations in ion drift time. With this method, we demonstrate that CCS values derived from multipass measurements closely align with those obtained from single-pass analyses, with an average deviation of 0.1%. We apply this method to characterize four isomeric trisaccharides. Our approach not only results in excellent agreement between our measured