Evidence map›Paper›PMID 38987502›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur.

Yoshihisa Ohashi, Kensuke Fukushima, Maho Tsuchiya, Hiroki Saito, Kentaro Uchida, Katsufumi Uchiyama, Naonobu Takahira, Masashi Takaso

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yoshihisa OhashiDepartment of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
Kensuke FukushimaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan. kenfu@r4.dion.ne.jp.ORCID http://orcid.org/0000-0001-8599-0872
Maho TsuchiyaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
Hiroki SaitoDepartment of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
Kentaro UchidaDepartment of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
Katsufumi UchiyamaDepartment of Patient Safety and Healthcare Administration, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
Naonobu TakahiraDepartment of Rehabilitation, Kitasato University School of Allied Health Sciences, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
Masashi TakasoDepartment of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study aimed to compare the impact of different broach surface designs on post-operative clinical outcomes, bone reactions and changes in bone mineral density (BMD) in patients who underwent total hip arthroplasty (THA) using a fully hydroxyapatite coated and double tapered stem with either compaction shape (COM) or hybrid shape (HYB) broaches. MATERIALS AND

methodsA retrospective analysis was conducted on 76 patients (100 hips) who underwent primary THA using the Avenir complete stem®. Patients were divided into two groups: the COM broach group (50 hips) and HYB broach group (50 hips). We evaluated clinical outcomes using the Japanese Orthopaedic Association hip scores one month before the surgery, and 12 and 24 months after the surgery. Radiographic findings, including stem alignment angles, radiolucent lines, spot welds, and cortical hypertrophy, were assessed. BMD around the stem in Gruen zones 1-7 was evaluated using dual-energy X-ray absorptiometry (DEXA) at 7 days, 12, and 24 months post-operatively. The Dorr classification was used to assess femoral morphology.

resultsThere were no significant differences in clinical outcomes, radiographic findings, or BMD changes between the COM and HYB broach groups in the overall patient cohort. However, in Dorr type A femurs, the COM broach group demonstrated superior BMD superior preservation in zones 1 and 7 after 12 months and in zones 1, 6 and 7 after 24 months. Additionally, in Dorr type B femurs, significant BMD preservation was observed in zone 3 at 24 months in the COM broach group.

conclusionsThis study suggests that the broach surface design of fully hydroxyapatite coated stems may influence periprosthetic BMD changes, especially in Dorr type A and B femurs. Surgeons should consider broach selection based on patient-specific femoral morphology to optimize BMD preservation in THA procedures using fully hydroxyapatite coated stems.

Indexed as

Arthroplasty, Replacement, HipBone DensityDurapatiteHip ProsthesisProsthesis DesignAbsorptiometry, PhotonAdultAgedFemaleFemurHumansMaleMiddle AgedRetrospective StudiesDurapatiteBone mineral densityBroach surface designDORR classificationFemoral morphologyFully hydroxyapatite-coated stemTotal hip arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.