Evidence map›Paper›PMID 38987160›Full record

ArticleMagnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine2025

Voxel-Based Morphometry of Progressive Supranuclear Palsy Using a 3D Fast Low-angle Shot Localizer Image: A Comparison with Magnetization-Prepared Rapid Gradient Echo.

Cong Shang, Shohei Inui, Daita Kaneda, Yuto Uchida, Hiroshi Toyama, Keita Sakurai, Yoshio Hashizume

Abstract readComparative Study
In one paragraph

Article in Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cong ShangDepartment of Radiology, National Center for Geriatrics and Gerontology, Obu, Aichi, Japan.
Shohei InuiDepartment of Radiology, The University of Tokyo, Tokyo, Japan.
Daita KanedaChoju Medical Institute, Fukushimura Hospital, Toyohashi, Aichi, Japan.
Yuto UchidaDepartment of Neurology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan.
Hiroshi ToyamaDepartment of Radiology, Fujita Health University, Toyoake, Aichi, Japan.
Keita SakuraiDepartment of Radiology, National Center for Geriatrics and Gerontology, Obu, Aichi, Japan.
Yoshio HashizumeChoju Medical Institute, Fukushimura Hospital, Toyohashi, Aichi, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVoxel-based morphometry (VBM) is widely used to investigate white matter (WM) atrophy in patients with progressive supranuclear palsy (PSP). In contrast to high-resolution 3D T1-weighted imaging such as magnetization-prepared rapid acquisition with gradient echo (MPRAGE) sequences, the utility of other 3D sequences has not been sufficiently evaluated. This study aimed to assess the feasibility of using a 3D fast low-angle shot sequence captured as a localizer image (L3DFLASH) for VBM analysis of WM atrophy patterns in patients with PSP.

methodsThis retrospective study included 12 patients with pathologically or clinically confirmed PSP, and 18 age- and sex-matched healthy controls scanned with both L3DFLASH and MPRAGE sequences. Image processing was conducted with the Computational Anatomy Toolbox 12 in statistical parametric mapping 12. In addition to the atrophic WM pattern of PSP on VBM, we assessed the WM volume agreement between the two sequences using simple linear regression and Bland-Altman plots.

resultsDespite the slightly larger clusters on MPRAGE, VBM using both sequences showed similar characteristics of PSP-related WM atrophy, including in the midbrain, pons, thalamus, and precentral gyrus. In contrast, VBM showed gray matter (GM) atrophy of the precuneus and right superior parietal lobule exclusively on L3DFLASH. Unlike the measured values of total intracranial volume, GM, and cerebrospinal fluid on MPRAGE, the value of WM was larger on L3DFLASH. In contrast to the total intracranial volume, brainstem, and frontal and occipital lobes, the correlation with WM volume in other regions was relatively low. However, the Bland-Altman plots demonstrated strong agreement, with over 90% of the values falling within the agreement limits.

conclusionBoth MPRAGE and L3DFLASH are useful for detecting PSP-related WM atrophy using VBM.

Indexed as

BrainImaging, Three-DimensionalMagnetic Resonance ImagingSupranuclear Palsy, ProgressiveWhite MatterAgedAged, 80 and overAtrophyFeasibility StudiesFemaleHumansImage Processing, Computer-AssistedMaleMiddle AgedRetrospective Studiesfast low-angle shot imagemagnetization-prepared rapid acquisition with gradient echoprogressive supranuclear palsythree-dimensional T1-weighted imagevoxel-based morphometry

Identifiers

PMID38987160
PMCPMC12406153

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.