Evidence map›Paper›PMID 38984138›Full record

ArticleFrontiers in ophthalmology2024

The effect of sampling window size on topographical maps of foveal cone density.

Emma Warr, Jenna Grieshop, Robert F Cooper, Joseph Carroll

Abstract read
In one paragraph

Article in Frontiers in ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. In Vivo Cone Photoreceptor Topography of the Human Foveola.Investigative ophthalmology & visual science · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Emma WarrDepartment of Ophthalmology & Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, United States.
Jenna GrieshopDepartment of Ophthalmology & Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, United States.
Robert F CooperDepartment of Ophthalmology & Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, United States.
Joseph CarrollDepartment of Ophthalmology & Visual Sciences, Medical College of Wisconsin, Milwaukee, WI, United States.

Funding

Clinical and Translational Science AwardUL1TR001436 · NCATS · MEDICAL COLLEGE OF WISCONSIN · PI FREED, JULIE K · 2015 to 2025
$47.5M
Assessing Photoreceptor Structure and Function in Normal and Diseased RetinaeR01EY017607 · NEI · MEDICAL COLLEGE OF WISCONSIN · PI Joseph Carroll · 2008 to 2026
$8.3M
Retinal Contributions to Vision Loss in AlbinismR01EY033580 · NEI · MEDICAL COLLEGE OF WISCONSIN · PI CARROLL, JOSEPH · 2022 to 2025
$2.2M
Validating Automated Photoreceptor Analytics Software For Degenerative Eye Disease Research and Biopharma Clinical Trials.R44EY031278 · NEI · TRANSLATIONAL IMAGING INNOVATIONS, INC. · PI BUCKLAND, ERIC L., CARROLL, JOSEPH · 2020 to 2021
$1.5M
VISION RES LAB: HERPETIC KERATIC, CORE PIGMENT GENES, RETINITIS PIGMENTOSAC06RR016511 · NCRR · MEDICAL COLLEGE OF WISCONSIN · PI DUNN, MICHAEL J · 2002 to 2002
$1.4M
NCATS NIH HHS UL1 TR001436NCRR NIH HHS C06 RR016511NEI NIH HHS R01 EY017607NEI NIH HHS R01 EY033580NEI NIH HHS R44 EY031278
6 · The paper itself

Abstract

Purpose: To characterize the effect of sampling window size on maps of foveal cone density derived from adaptive optics scanning light ophthalmoscope (AOSLO) images of the cone mosaic. Methods: Forty-four AOSLO-derived montages of the foveal cone mosaic (300 x 300µm) were used for this study (from 44 individuals with normal vision). Cone photoreceptor coordinates were semi-automatically identified by one experienced grader. From these coordinates, cone density matrices across each foveal montage were derived using 10 different sampling window sizes containing 5, 10, 15, 20, 40, 60, 80, 100, 150, or 200 cones. For all 440 density matrices, we extracted the location and value of peak cone density (PCD), the cone density centroid (CDC) location, and cone density at the CDC. Results: Across all window sizes, PCD values were larger than those extracted at the CDC location, though the difference between these density values decreased as the sampling window size increased (p<0.0001). Overall, both PCD (r=-0.8099, p=0.0045) and density at the CDC (r=-0.7596, p=0.0108) decreased with increasing sampling window size. This reduction was more pronounced for PCD, with a 27.8% lower PCD value on average when using the 200-cone versus the 5-cone window (compared to only a 3.5% reduction for density at the CDC between these same window sizes). While the PCD and CDC locations did not occur at the same location within a given montage, there was no significant relationship between this PCD-CDC offset and sampling window size (p=0.8919). The CDC location was less variable across sampling windows, with an average per-participant 95% confidence ellipse area across the 10 window sizes of 47.56µm² (compared to 844.10µm² for the PCD location, p<0.0001). Conclusion: CDC metrics appear more stable across varying sampling window sizes than PCD metrics. Understanding how density values change according to the method used to sample the cone mosaic may facilitate comparing cone density data across different studies.

Indexed as

adaptive opticscone densitycone spacingfovearetina

Identifiers

PMID38984138
PMCPMC11182112

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.