ArticleTranslational andrology and urology2024

Performance evaluation and clinical application of the UA-5600 automatic dry chemistry urine analyzer in renal diseases.

Yin Liu, Xiaohe Zheng, Dong Wang, Fei Fang, Yao Chen, Mengzhi Hong, Jiali Wu, Chi Zhang, Yangyang Qiao, Iyare Izevbaye and 1 more

Abstract read
In one paragraph

Article in Translational andrology and urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Yin Liu *Department of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Xiaohe Zheng *Department of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Dong WangDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Fei FangDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Yao ChenDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Mengzhi HongDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Jiali WuDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Chi ZhangDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Yangyang QiaoDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Iyare IzevbayeDepartment of Pathology and Laboratory Medicine, Emory University School of Medicine, Grady Health System, Atlanta, GA, USA.
Shihong ZhangDepartment of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Urine testing as a routine screening programme, abnormal test results can be suggestive to clinicians but can sometimes be overlooked, and the establishment of a diagnostic model can better assist clinicians in identifying potential problems. BLD (blood), LEU (leukocyte), PRO (protein) and GLU (glucose) are the four most important parameters in urine testing, and the accuracy of their results is a key concern for clinicians, so it is essential to verify the accuracy of their results. In this study, we evaluated the analytical and clinical performance of Mindray's automatic urine dry chemistry analyzer, the UA-5600 (Hereinafter referred to as the (UA-5600), and the test strips configured with the instrument, and developed a machine-learning (ML) model for kidney disease screening from the results of 11 parameters output from the UA-5600 with the aim of detecting abnormal urine test results. Methods: Urine samples from outpatients and inpatients at The First Affiliated Hospital of Sun Yat-sen University were collected from August to September 2022 to evaluate the performance of the Mindray UA-5600 dry chemistry analyzer and test strips. The evaluation of the UA-5600 and its test strips focused on the agreement of the urine BLD and LEU readings with the RBC (red blood cell) and WBC (white blood cell) counts obtained by the Mindray EH-2090 urine formed element analyzer. We also compared the PRO and GLU readings with the results of the Mindray BS-2800M biochemistry analyzer. Urine samples from outpatients and inpatients were retrospectively analysed and grouped according to LIS diagnosis. Additionally, eight ML models for kidney disease screening were developed using 11 parameters measured by the UA-5600. And the model was validated by the validation set. Results: The UA-5600 had an 89.55% concordance rate for BLD and a 91.04% concordance rate for LEU compared to the EH-2090 analyzer. When benchmarked against the BS-2800M, the concordance rates for PRO and GLU were 94.14% and 95.20%, respectively. A total of 1,691 samples were used for the construction of the ML models, of which 346 patients (135 males and 211 females, age range: 18 to 98 years) diagnosed with renal disease, and 1,345 patients (397 males and 948 females, age range: 18 to 92 years) with non-renal disease diagnosed with other conditions. Notably, the Naïve Bayes (NB) model, which was built from the UA-5600 parameters, demonstrated superior predictive capabilities for renal disease, with an area under the receiver operating characteristic curve of 0.9470, a sensitivity of 0.7767, and a specificity of 0.9457. Conclusions: The Mindray UA-5600 demonstrates robust detection abilities for both BLD and LEU, and its results for PRO and GLU align closely with those obtained from the chemistry analyzer. The NB model has a good screening ability and shows promise as an effective screening tool.

Indexed as

Automatic dry chemistry urine analyzerML modelsrenal diseaseUA-5600

Identifiers

PMID38983473
PMCPMC11228674