Evidence map›Paper›PMID 38983009›Full record

ArticleFrontiers in ophthalmology2023

Complications of pupil expansion devices: a large real-world study.

Tal Yahalomi, Omar Elhaddad, Venkata Avadhanam, Derek Tole, Kieran Darcy, Eliya Levinger, Raimo Tuuminen, Asaf Achiron

Abstract read
In one paragraph

Article in Frontiers in ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tal YahalomiDepartment of Ophthalmology, Samson Assuta Ashdod Hospital, Faculty of Health Sciences, Ben-Gurion University of the Negev, Be'er Sheva, Israel.
Omar ElhaddadBristol Eye Hospital, University Hospitals Bristol NHS Foundation Trust, Bristol, United Kingdom.
Venkata AvadhanamBristol Eye Hospital, University Hospitals Bristol NHS Foundation Trust, Bristol, United Kingdom.
Derek ToleBristol Eye Hospital, University Hospitals Bristol NHS Foundation Trust, Bristol, United Kingdom.
Kieran DarcyBristol Eye Hospital, University Hospitals Bristol NHS Foundation Trust, Bristol, United Kingdom.
Eliya LevingerOphthalmology Department, Soraski Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel.
Raimo Tuuminen *Department of Ophthalmology, Kymenlaakso Central Hospital, Kotka, Finland.
Asaf Achiron *Ophthalmology Department, Soraski Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To assess the risk for uveitis, pseudophakic cystoid macular edema (PCME), and posterior capsular opacification (PCO) associated with the use of pupil expansion devices in cataract surgery. Design: A retrospective comparative cohort study. Participants: Patients who underwent routine cataract surgery with and without pupil expansion devices at the Department of Ophthalmology, Bristol Eye Hospital, UK, between January 2008 and December 2017. Methods: This study included 39,460 eyes operated without a pupil expansion device and 699 eyes operated with the device. Odds ratios for uveitis and PCME when using a pupil expansion device were calculated using univariate and multivariate regression analysis, having age, gender, diabetes, pseudoexfoliation, and pupil expansion device as independent variables. Multivariate Cox regression controlling for age and gender was used to estimate hazard ratios (HR) for Nd : YAG laser capsulotomies. Results: Postoperative uveitis and PCME were reported in 3.9% and 2.7% of the eyes operated with a pupil expansion device compared to 2.3% and 1.3% operated without the device (p=0.005 and p=0.002, respectively). In univariate regression analysis, eyes with pupil expansion devices showed a higher risk of postoperative uveitis or PMCE after cataract surgery (OR 1.88, 95%CI 1.39-2.55, p<0.001). In multivariate regression analysis, the risk for PMCE was greater among diabetic patients and in eyes with a pupil expansion device than in those without (OR 1.50, 95%CI 1.24-1.83, Conclusion: In our large cohort study, the use of pupil expansion devices in cataract surgery was associated with an increased risk of major postoperative complications. Effective anti-inflammatory treatment and follow-up are warranted in eyes operated with a pupil expansion device.

Indexed as

cataract surgeryposterior capsular opacificationpseudophakic cystoid macular edemapupil expansion deviceuveitis

Identifiers

PMID38983009
PMCPMC11182085

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.