ArticleRespiratory care2024

Development of a New Method for Evaluating Heat and Moisture Exchanger Performance.

Kouhei Nagata, Tomio Andoh, Ken Kishimoto, Kunihisa Eguchi, Yutaka Usuda, Toshihiro Tsuji, Go Hirabayashi, Koichi Maruyama

Abstract readEvaluation Study
In one paragraph

Article in Respiratory care, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Kouhei NagataDepartment of Anesthesiology, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan.
Tomio AndohDepartment of Anesthesiology, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan. tandoh@med.teikyo-u.ac.jp.
Ken KishimotoDepartment of Anesthesiology, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan.
Kunihisa EguchiDepartment of Anesthesiology, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan.
Yutaka UsudaDepartment of Critical Care Medicine, Yokosuka Kyousai Hospital, Yokosuka, Japan.
Toshihiro TsujiDivision of Medical Engineering, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan.
Go HirabayashiDepartment of Anesthesiology, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan.
Koichi MaruyamaDepartment of Anesthesiology, Teikyo University School of Medicine Hospital Mizonokuchi, Kawasaki, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA model system described in International Organization for Standardization 9360 is the standard method for estimating the humidifying performance of heat and moisture exchangers (HMEs). However, there are no reliable bedside methods for evaluating the ongoing humidification performance of HMEs. Therefore, this study aimed to develop 2 clinically applicable methods for estimating the ongoing humidifying performance of HMEs and to evaluate their reliability in a model system.

methodsPhysiologically expired gas was simulated using a heated humidifier, and ventilation was delivered using a ventilator with constant flow through 3 different types of HMEs. Relative humidity (RH) was measured using a capacitive-type moisture sensor. Water content lost during expiration was calculated by integrating absolute humidity (AH), instantaneous gas flow measured at the expiratory outlet of the ventilator, and time. We also calculated the water content released and captured by the HMEs during tidal ventilation by integrating the difference in AH across the HMEs, instantaneous gas flow, and time.

resultsWe found that the RH, temperature, and AH were almost constant on the expiratory outlet of the ventilator but rapidly varied near the HMEs. The water content lost by the 3 HMEs was associated with the manufacturer-reported values and inversely correlated with the calculated values of the water content exchanged by the HMEs. The water content released and captured by HMEs was closely correlated with the difference in HME weight measured at the end of inspiration and expiration; however, the water content captured by HMEs seemed to be overestimated.

conclusionsOur results demonstrated that our system was able to detect the differences in the performance of 3 models of HMEs and suggest that our method for calculating water loss is reliable for estimating the water retention performance of HMEs during mechanical ventilation, even in the presence of a constant flow.

Indexed as

Hot TemperatureHumidifiersHumidityEquipment DesignHumansReproducibility of ResultsRespiration, ArtificialVentilators, MechanicalWaterWaterHeat and moisture exchangerhumidificationhumiditymechanical ventilationwater contentwater exchangewater retention

Identifiers

PMID38981654
PMCPMC11469012

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.