Evidence map›Paper›PMID 38980625›Full record

ArticleJournal of imaging informatics in medicine2025

Minimal Detectable Bone Fracture Gaps in CT Images and Digital Three-Dimensional (3D) Radii Models.

Martin Bittner-Frank, Andreas Strassl, Ewald Unger, Lena Hirtler, Barbara Eckhart, Markus Koenigshofer, Alexander Stoegner, Kevin Staats, Franz Kainberger, Reinhard Windhager and 2 more

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Martin Bittner-FrankDepartment of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.ORCID http://orcid.org/0000-0002-8740-3923
Andreas StrasslDepartment of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0002-7320-0279
Ewald UngerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0003-0275-9988
Lena HirtlerCenter for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0001-5194-9118
Barbara EckhartDepartment of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
Markus KoenigshoferCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0003-4671-6701
Alexander StoegnerDepartment of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.ORCID http://orcid.org/0000-0003-0029-6748
Kevin StaatsDepartment of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.ORCID http://orcid.org/0000-0002-3459-5773
Franz KainbergerDepartment of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0002-1823-971X
Reinhard WindhagerDepartment of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.ORCID http://orcid.org/0000-0002-6321-1804
Francesco MoscatoCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0003-0279-6615
Emir BencaDepartment of Orthopedics and Trauma Surgery, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria. emir.benca@muv.ac.at.ORCID http://orcid.org/0000-0002-9029-7172

Funding

Österreichische Forschungsförderungsgesellschaft 858060
6 · The paper itself

Abstract

Knowledge of the minimal detectable bone fracture gap is essential in three-dimensional (3D) models, particularly in pre-operative planning of osteosynthesis to avoid overlooking gaps. In this study, defined incisions and bony displacements ranging from 100 to 400 µm were created in diaphyseal radii in 20 paired forearm specimens and verified with light microscopy. The specimens were scanned utilizing different computed tomography (CT) technologies/scanners, specimen positionings, scan protocols, image segmentations, and processing protocols. Inter- and intra-operator variabilities were reported as coefficient kappa. In CT images, fracture gaps of 100 µm and bone lamellae of 300 µm and 400 µm width were identified at a rate of 80 to 100%, respectively, independent of the investigated settings. In contrast, only 400µm incisions and bony displacements were visible in digital 3D models, with detection rates dependent on CT technology, image segmentation, and post-processing algorithm. 3D bone models based on state-of-the-art CT imaging can reliably visualize clinically relevant bone fracture gap sizes. However, verification of fractures to be surgically addressed should be verified with the original CT image series.

Indexed as

Imaging, Three-DimensionalRadiusRadius FracturesTomography, X-Ray ComputedAgedAlgorithmsFemaleHumansMaleMiddle AgedComputed tomographyComputerized modelsDimensional measurement accuracyTrauma surgeryWrist fracture

Identifiers

PMID38980625
PMCPMC11811335

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.