Agreement and repeatability of scotopic pupil size measurement with the 2WIN-S portable refractor in Chinese adults.

Yibing Zhou, Xingru He, Ziming Liu, Ling Xu, Liangzhe Li, Jiayan Chen, Jiahui Zhao, Ruyi Li, Chunhong Yan, Cui Yu and 4 more

Abstract readObservational Study
In one paragraph

Observational study in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Yibing ZhouSchool of Public Health, Dalian Medical University, Dalian, China.
Xingru HeSchool of Public Health, He University, Shenyang, China.
Ziming LiuSchool of Public Health, He University, Shenyang, China.
Ling XuDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China.
Liangzhe LiDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China.
Jiayan ChenDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China.
Jiahui ZhaoDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China.
Ruyi LiSchool of Public Health, Dalian Medical University, Dalian, China.
Chunhong YanSchool of Public Health, He University, Shenyang, China.
Cui YuSchool of Optometry, He University, Shenyang, China.
Fei YuSchool of Public Health, He University, Shenyang, China.
Wei HeDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China.
Guanghao QinDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China. qinguanghao2020@163.com.
Sile YuDepartment of Clinical Research, He Eye Specialist Hospital, Shenyang, China. yusile@hsyk.com.cn.

Funding

Natural Science Foundation of Liaoning Province of China 2022-BS-345
6 · The paper itself

Abstract

To assess the agreement and repeatability of scotopic pupil size measurement using 2WIN-S (Adaptica, Padova, Italy) portable refractor in Chinese adults. This prospective non-randomized open-label controlled study assessed the scotopic pupil size of 100 right eyes using OPD-Scan III (Optical path difference) (Nidek Technologies, Gamagori, Japan) and 2WIN-S. OPD-Scan III and 2WIN-S measure pupil size using infrared light and detector, while 2WIN-S measures bilateral eyes simultaneously, OPD-Scan III measures unilateral eyes individually. Participants were first measured once using OPD-Scan III and two consecutive measurements were performed using 2WIN-S after 15 min of rest interval. The primary outcome was to evaluate the agreement between 2WIN-S and OPD-Scan III, and the secondary outcome was to evaluate the repeatability of 2WIN-S. Scotopic pupil size of 100 right eyes of 100 adults (28 male and 72 female) aged 18-53 years (mean 36 ± 12 years) was assessed using OPD-Scan III and 2WIN-S, respectively. The mean scotopic pupil size of OPD-Scan III and 2WIN-S was recorded to be 6.24 ± 0.88 mm and 6.27 ± 0.81 mm, respectively. For the mean scotopic pupil size of OPD-Scan III and 2WIN-S the difference was - 0.03 mm (95%CI - 0.10 to 0.04 mm), p = 0.445, the 95% limits of agreement (LOA) was - 0.71 to 0.66 mm. ICC between the two devices was 0.92 (95% CI 0.88-0.94) (ICC > 0.9 indicates excellent consistency). Coefficients of repeatability (CoR) of 2WIN-S was 0.37, which has a high repeatability. For the mean scotopic pupil size of 2WIN-S of the repeated measurements, the difference was -0.04 mm (95%CI - 0.08 to 0.01 mm), p = 0.019, the 95% limits of agreement (LOA) was - 0.41 to 0.32 mm, with a narrow LOA. However, the majority of the variations were less than ± 0.50 mm (98% of scotopic pupil size measurements were below this threshold), within the clinically acceptable range (± 0.50 mm). Our study showed excellent agreement between 2WIN-S and OPD-Scan III (ICC > 0.9) and a good repeatability of 2WIN-S (CoR = 0.37). This study suggests a novel technique for measuring pupillary responses in low light conditions, which can be considered an alternative to OPD-Scan III in clinical settings.

Indexed as

PupilAdolescentAdultChinaEast Asian PeopleFemaleHumansMaleMiddle AgedProspective StudiesReproducibility of ResultsYoung Adult

Identifiers

PMID38977905
PMCPMC11231274

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.