ArticlePediatric research2025
Slowing lung deflation by increasing the expiratory resistance enhances FRC in preterm rabbits.
Article in Pediatric research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- What CPAP to use in the delivery room? Bench comparison of two methods to provide continuous positive airways pressure in neonates.BMJ paediatrics open · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAs very preterm infants have surfactant-deficient and highly incompliant lungs, slowing lung deflation during expiration might help preserve functional residual capacity(FRC) during lung aeration. In this study, we investigated the effect of expiratory resistance(Re) on lung aeration during positive pressure ventilation in preterm rabbits immediately after birth.
methodsPreterm rabbit pups were delivered at 29 days gestation, mechanically ventilated from birth and simultaneously imaged to measure lung aeration using phase-contrast X-ray. Re was varied by altering the length (0, 60 or 1000 mm) of the expiratory circuit.
resultsIncreasing Re led to a decrease in lung deflation rates and both peak expiratory flows and flow rates at mid-deflation. As a result, the rate of de-acceleration(slowing) in lung deflation when approaching FRC was markedly reduced with increasing resistance. During lung aeration, FRC was significantly different between resistance groups and was significantly higher over time in the high compared to the low resistance group. While FRC values tended to be higher with higher Re, they were not significantly different at end-ventilation (t = 7 min).
conclusionIncreasing Re of the ventilation circuit during lung aeration in preterm rabbits immediately after birth decreased lung deflation rates and increased the accumulation of FRC over time. IMPACT: The expiratory phase of the ventilatory cycle has been largely overlooked as an opportunity to improve ventilation in preterm infants after birth. Increasing the expiratory resistance of the ventilator circuit during lung aeration in preterm rabbits immediately after birth markedly decreased lung deflation rates and increased FRC accumulation, compared to a low expiratory resistance. This indicates that ventilation devices that reduce the "work of breathing" by reducing the expiratory resistance, may have the unintended effect of reducing FRC, particularly in extremely preterm infants that have surfactant deficient highly incompliant lungs.
Indexed as
Identifiers
38977795What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.