Evidence map›Paper›PMID 38977533›Full record

ArticleEJNMMI physics2024

Deep learning based bilateral filtering for edge-preserving denoising of respiratory-gated PET.

Jens Maus, Pavel Nikulin, Frank Hofheinz, Jan Petr, Anja Braune, Jörg Kotzerke, Jörg van den Hoff

Abstract read
In one paragraph

Article in EJNMMI physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jens Maus *Department of Positron Emission Tomography, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314, Dresden, Germany. j.maus@hzdr.de.ORCID http://orcid.org/0000-0002-7195-9927
Pavel Nikulin *Department of Positron Emission Tomography, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314, Dresden, Germany.ORCID https://orcid.org/0000-0002-4568-4018
Frank HofheinzDepartment of Positron Emission Tomography, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314, Dresden, Germany.ORCID https://orcid.org/0000-0001-8016-4643
Jan PetrDepartment of Positron Emission Tomography, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314, Dresden, Germany.ORCID https://orcid.org/0000-0002-3201-6002
Anja BrauneKlinik und Poliklinik für Nuklearmedizin, Universtitätsklinikum Carl Gustav Carus, Fetscherstraße 74, 01307, Dresden, Germany.ORCID https://orcid.org/0000-0001-7707-9413
Jörg KotzerkeKlinik und Poliklinik für Nuklearmedizin, Universtitätsklinikum Carl Gustav Carus, Fetscherstraße 74, 01307, Dresden, Germany.
Jörg van den HoffDepartment of Positron Emission Tomography, Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01314, Dresden, Germany.ORCID https://orcid.org/0000-0003-4039-4780

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundResidual image noise is substantial in positron emission tomography (PET) and one of the factors limiting lesion detection, quantification, and overall image quality. Thus, improving noise reduction remains of considerable interest. This is especially true for respiratory-gated PET investigations. The only broadly used approach for noise reduction in PET imaging has been the application of low-pass filters, usually Gaussians, which however leads to loss of spatial resolution and increased partial volume effects affecting detectability of small lesions and quantitative data evaluation. The bilateral filter (BF) - a locally adaptive image filter - allows to reduce image noise while preserving well defined object edges but manual optimization of the filter parameters for a given PET scan can be tedious and time-consuming, hampering its clinical use. In this work we have investigated to what extent a suitable deep learning based approach can resolve this issue by training a suitable network with the target of reproducing the results of manually adjusted case-specific bilateral filtering.

methodsAltogether, 69 respiratory-gated clinical PET/CT scans with three different tracers (

resultsThe automated procedure used for filter parameter determination chose adequate filter parameters for the majority of the data sets with only 19 patient data sets requiring manual tuning. Evaluation of the focal uptake ROIs revealed that CNN as well as BF based filtering essentially maintain the focal

conclusionsOur results show that a neural network based denoising can reproduce the results of a case by case optimized BF in a fully automated way. Apart from rare cases it led to images of practically identical quality regarding noise level, edge preservation, and signal recovery. We believe such a network might proof especially useful in the context of improved motion correction of respiratory-gated PET studies but could also help to establish BF-equivalent edge-preserving CNN filtering in clinical PET since it obviates time consuming manual BF parameter tuning.

Indexed as

Deep learningImage denoisingImage quantificationMotion correctionNeural networksPositron emission tomography (PET)Post-filteringRespiratory gating

Identifiers

PMID38977533
PMCPMC11231129

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.