Evidence map›Paper›PMID 38977529›Full record

ArticleAnnals of biomedical engineering2024

Development of a Novel Soft Tissue Measurement Device for Individualized Finite Element Modeling in Custom-Fit CPAP Mask Evaluation.

Erica Martelly, Summer Lee, Kristina Martinez, Sandeep Rana, Kenji Shimada

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Erica MartellyDepartment of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA. emartell@andrew.cmu.edu.ORCID http://orcid.org/0000-0002-9020-0078
Summer LeeDepartment of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.
Kristina MartinezDepartment of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.
Sandeep RanaDepartment of Neurology, Allegheny General Hospital, 490 E North Avenue, Pittsburgh, PA, 15212, USA.
Kenji ShimadaDepartment of Mechanical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.

Funding

Highmark Foundation A022774
6 · The paper itself

Abstract

purposeIndividual facial soft tissue properties are necessary for creating individualized finite element (FE) models to evaluate medical devices such as continuous positive airway pressure (CPAP) masks. There are no standard tools available to measure facial soft tissue elastic moduli, and techniques in literature require advanced equipment or custom parts to replicate.

methodsWe propose a simple and inexpensive soft tissue measurement (STM) indenter device to estimate facial soft tissue elasticity at five sites: chin, cheek near lip, below cheekbone, cheekbone, and cheek. The STM device consists of a probe with a linear actuator and force sensor, an adjustment system for probe orientation, a head support frame, and a controller. The device was validated on six ballistics gel samples and then tested on 28 subjects. Soft tissue thickness was also collected for each subject using ultrasound.

resultsThickness and elastic modulus measurements were successfully collected for all subjects. The mean elastic modulus for each site is E

conclusionOverall, the STM provides a first estimate of facial soft tissue elasticity and is affordable and easy to build with mostly off-the-shelf parts. These values can be used to create personalized FE models to evaluate custom-fit CPAP masks.

Indexed as

Continuous Positive Airway PressureElastic ModulusFinite Element AnalysisMasksAdultFaceFemaleHumansMaleMiddle AgedModels, BiologicalElastic modulusFaceIndenterMaterial propertiesSoft tissue

Identifiers

PMID38977529
PMCPMC11560986

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.