Evidence map›Paper›PMID 38975634›Full record

ArticleInternational journal of occupational medicine and environmental health2024

Analysis of dose distribution around a computed tomography scanner in terms of exposure to scattered ionizing radiation of caregivers of pediatric patients.

Michał Biegała, Marcin Brodecki, Krystian Skoczylas, Teresa Jakubowska, Joanna Domienik-Andrzejewska

Abstract read
In one paragraph

Article in International journal of occupational medicine and environmental health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Michał BiegałaMedical University of Lodz, Łódź, Poland (Faculty of Medicine, Department of Medical Imaging Technology).
Marcin BrodeckiNofer Institute of Occupational Medicine, Łódź, Poland.
Krystian SkoczylasPolish Mother's Memorial Hospital Research Institute, Łódź, Poland (Department of Diagnostic Imaging).
Teresa JakubowskaMedical University of Lodz, Łódź, Poland (Faculty of Medicine, Department of Medical Imaging Technology).
Joanna Domienik-AndrzejewskaNofer Institute of Occupational Medicine, Łódź, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesDuring computed tomography (CT), a large amount of ionizing radiation is emitted to ensure high quality of the obtained radiological image. This study measured the dose distribution around the CT scanner and the exposure of people staying near the CT scanner during the examination. MATERIAL AND

methodsThe measurements used an anthropomorphic phantom to assess human exposure to ionizing radiation. The probability of inducing leukemia and other cancers as a result of absorbing doses recorded around the CT device was also calculated.

resultsThe highest exposure to scattered radiation in the proximity of the CT scanner is recorded at the gantry of the tomograph, i.e., 55.7 μGy, and the lowest, below lower detection limit of 6 μGy at the end of the diagnostic table. The whole-body detector placed on the anthropomorphic phantom located at the diagnostic table right next to the CT gantry recorded 59.5 μSv and at the end of the table 1.5 μSv. The average doses to the lenses in these locations were: 32.1 μSv and 2.9 μSv, respectively.

conclusionsThe probability of induction of leukemia or other types of cancer is low, but the need for people to stay in the examination room during a CT examination should be limited to the necessary minimum. Int J Occup Med Environ Health. 2024;37(3):326-34.

Indexed as

Phantoms, ImagingRadiation DosageTomography, X-Ray ComputedCaregiversChildHumansOccupational ExposureRadiation ExposureRadiation, IonizingScattering, RadiationTomography Scanners, X-Ray ComputedCT scannereffective doseleukemiapediatric radiologyprobability of induction of leukemiaradiological protection

Identifiers

PMID38975634
PMCPMC11424147

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.