Evidence map›Paper›PMID 38974929›Full record

ReviewResuscitation plus2024

Newborn heart rate monitoring methods at birth and clinical outcomes: A systematic review.

Vishal S Kapadia, Mandira D Kawakami, Marya L Strand, Callum Gately, Angela Spencer, Georg M Schmölzer, Yacov Rabi, Johnathan Wylie, Gary Weiner, Helen G Liley and 2 more

Abstract readReview
In one paragraph

Review in Resuscitation plus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Singapore Neonatal Resuscitation Guidelines 2026.Singapore medical journal · 2026
    Guideline
  2. Article
  3. Observational
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Vishal S KapadiaUniversity of Texas Southwestern Medical Center, Dallas, TX, United States.
Mandira D KawakamiFederal University of Sao Paulo, Sao Paulo, Brazil.
Marya L StrandAkron Children's Hospital, Akron, OH, United States.
Callum GatelyUniversity of Otago, Wellington, New Zealand.
Angela SpencerSaint Louis University, St. Louis, MO, United States.
Georg M SchmölzerUniversity of Alberta, Edmonton, Alberta, Canada.
Yacov RabiUniversity of Calgary, Calgary, Alberta, Canada.
Johnathan WylieJames Cook University Hospital, Middlesbrough, United Kingdom.
Gary WeinerUniversity of Michigan, Ann Arbor, MI 48109, United States.
Helen G LileyUniversity of Queensland, Australia.
Myra H WyckoffUniversity of Texas Southwestern Medical Center, Dallas, TX, United States.
International Liaison Committee on Resuscitation Neonatal Life Support Task Force

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: Compare heart rate assessment methods in the delivery room on newborn clinical outcomes. Methods: A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283438) Study Selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence. Results: Two randomized controlled trials involving 91 newborns and 1 nonrandomized study involving 632 newborns comparing electrocardiogram (ECG) to auscultation plus pulse oximetry were included. No studies were found that compared any other heart rate measurement methods and reported clinical outcomes. There was no difference between the ECG and control group for duration of positive pressure ventilation, time to heart rate ≥ 100 beats per minute, epinephrine use or death before discharge. In the randomized studies, there was no difference in rate of tracheal intubation [RR 1.34, 95% CI (0.69-2.59)]. No participants received chest compressions. In the nonrandomized study, fewer infants were intubated in the ECG group [RR 0.75, 95% CI (0.62-0.90)]; however, for chest compressions, benefit or harm could not be excluded. [RR 2.14, 95% (CI 0.98-4.70)]. Conclusion: There is insufficient evidence to ascertain clinical benefits or harms associated with the use of ECG versus pulse oximetry plus auscultation for heart rate assessment in newborns in the delivery room.

Indexed as

AuscultationBradycardiaDigital stethoscopeDoppler ultrasoundDry electrode ECGElectrocardiogramHeart RateILCORMeta-analysisNewbornNRPPalpationPulse oximeterResuscitationSystematic review

Identifiers

PMID38974929
PMCPMC11225902

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.