ArticleBMC musculoskeletal disorders2024
Clinical study on freehand of bicortical sacral screw fixation with the assistance of torque measurement device.
Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSacral screw loosening is a typical complication after internal fixation surgery through the vertebral arch system. Bicortical fixation can successfully prevent screw loosening, and how improving the rate of bicortical fixation is a challenging clinical investigation.
objectiveTo investigate the feasibility of improving the double corticality of sacral screws and the optimal fixation depth to achieve double cortical fixation by combining the torque measurement method with bare hands.
methodsNinety-seven cases of posterior lumbar internal fixation with pedicle root system were included in this study. Based on the tactile feedback of the surgeon indicating the expected penetration of the screw into the contralateral cortex of the sacrum, the screws were further rotated by 180°, 360°, or 720°, categorized into the bicortical 180° group, bicortical 360° group, and bicortical 720° group, respectively. Intraoperatively, the torque during screw insertion was recorded. Postoperatively, the rate of double-cortex engagement was evaluated at 7 days, and screw loosening was assessed at 1 year follow-up.
resultsThe bicortical rates of the 180° group, 360° group, and 720° group were 66.13%, 91.18% and 93.75%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05).The rates of loosening of sacral screws in the 180° group, 360° group, and 720° group were 20.97%, 7.35% and 7.81%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05). The bicortical 360° group achieved a relatively satisfactory rate of dual cortical purchase while maintaining a lower rate of screw loosening.
conclusionManual insertion of sacral screws with the assistance of a torque measurement device can achieve a relatively satisfactory dual cortical purchase rate while reducing patient hospitalization costs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.