Evidence map›Paper›PMID 38969693›Full record

ArticleScientific reports2024

Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis.

Ning Li, Kai-Yuan Cheng, Jixing Fan, Yu Li, Minghui Yang, Shiwen Zhu, Xieyuan Jiang

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ning LiDepartment of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Kai-Yuan ChengDepartment of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Jixing FanDepartment of Orthopedics, Peking University Third Hospital, Beijing, 100191, China.
Yu LiCollege of Engineering, China Agricultural University, Beijing, 100083, China.
Minghui YangDepartment of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Shiwen ZhuDepartment of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China. doctorzhujst@163.com.
Xieyuan JiangDepartment of Orthopaedics and Traumatology, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.

Funding

Beijing Municipal Science & Technology Commission Z211100002921056the National Key Research and Development Program of China 2021YFC2501700
6 · The paper itself

Abstract

The selection of implants for fixing unstable femoral neck fractures (FNF) remains contentious. This study employs finite element analysis to examine the biomechanics of treating Pauwels type III femoral neck fractures using cannulated compression screws (3CS), biplane double-supported screw fixation (BDSF), and the femoral neck system (FNS). A three-dimensional model of the proximal femur was developed using computed tomography scans. Fracture models of the femoral neck were created with 3CS, BDSF, and FNS fixations. Von Mises stress on the proximal femur, fracture ends, internal fixators, and model displacements were assessed and compared across the three fixation methods (3CS, BDSF, and FNS) during the heel strike of normal walking. The maximum Von Mises stress in the proximal fragment was significantly higher with 3CS fixation compared to BDSF and FNS fixations (120.45 MPa vs. 82.44 MPa and 84.54 MPa, respectively). Regarding Von Mises stress distribution at the fracture ends, the highest stress in the 3CS group was 57.32 MPa, while BDSF and FNS groups showed 51.39 MPa and 49.23 MPa, respectively. Concerning implant stress, the FNS model exhibited greater Von Mises stress compared to the 3CS and BDSF models (236.67 MPa vs. 134.86 MPa and 140.69 MPa, respectively). Moreover, BDSF displayed slightly lower total displacement than 3CS fixation (7.19 mm vs. 7.66 mm), but slightly higher displacement than FNS (7.19 mm vs. 7.03 mm). This study concludes that BDSF outperforms 3CS fixation in terms of biomechanical efficacy and demonstrates similar performance to the FNS approach. As a result, BDSF stands as a dependable alternative for treating Pauwels type III femoral neck fractures.

Indexed as

Bone ScrewsFemoral Neck FracturesFinite Element AnalysisFracture Fixation, InternalBiomechanical PhenomenaHumansStress, MechanicalTomography, X-Ray ComputedBiplane double-supported screw fixation (BDSF)Cannulated compression screws (3CS)Femoral neck fractureFemoral neck system (FNS)Finite element analysis

Identifiers

PMID38969693
PMCPMC11226618

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked