Evidence map›Paper›PMID 38968191›Full record

ArticlePloS one2024

Verification of the effect of data-driven brain motion correction on PET imaging.

Hayato Odagiri, Hiroshi Watabe, Kentaro Takanami, Kazuma Akimoto, Akihito Usui, Hirofumi Kawakami, Akie Katsuki, Nozomu Uetake, Yutaka Dendo, Yoshitaka Tanaka and 3 more

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Hayato OdagiriDepartment of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.ORCID 0000-0002-9055-305X
Hiroshi WatabeDivision of Radiation Protection and Safety Control, Cyclotron and Radioisotope Center, Tohoku University, Sendai, Miyagi, Japan.
Kentaro TakanamiDepartment of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.ORCID 0000-0002-0098-7760
Kazuma AkimotoDepartment of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
Akihito UsuiDepartment of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
Hirofumi KawakamiGE HealthCare Japan, Tokyo, Japan.
Akie KatsukiGE HealthCare Japan, Tokyo, Japan.
Nozomu UetakeGE HealthCare Japan, Tokyo, Japan.
Yutaka DendoDepartment of Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
Yoshitaka TanakaDepartment of Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
Hiroyasu KodamaDepartment of Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
Kei TakaseDepartment of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
Tomohiro KanetaDepartment of Diagnostic Image Analysis, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionBrain positron emission tomography/computed tomography (PET/CT) scans are useful for identifying the cause of dementia by evaluating glucose metabolism in the brain with F-18-fluorodeoxyglucose or Aβ deposition with F-18-florbetaben. However, since imaging time ranges from 10 to 30 minutes, movements during the examination might result in image artifacts, which interfere with diagnosis. To solve this problem, data-driven brain motion correction (DDBMC) techniques are capable of performing motion corrected reconstruction using highly accurate motion estimates with high temporal resolution. In this study, we investigated the effectiveness of DDBMC techniques on PET/CT images using a Hoffman phantom, involving continuous rotational and tilting motion, each expanded up to approximately 20 degrees. MATERIALS AND

methodsListmode imaging was performed using a Hoffman phantom that reproduced rotational and tilting motions of the head. Brain motion correction processing was performed on the obtained data. Reconstructed images with and without brain motion correction processing were compared. Visual evaluations by a nuclear medicine specialist and quantitative parameters of images with correction and reference still images were compared.

resultsNormalized Mean Squared Error (NMSE) results demonstrated the effectiveness of DDBMC in compensating for rotational and tilting motions during PET imaging. In Cases 1 and 2 involving rotational motion, NMSE decreased from 0.15-0.2 to approximately 0.01 with DDBMC, indicating a substantial reduction in differences from the reference image across various brain regions. In the Structural Similarity Index (SSIM), DDBMC improved it to above 0.96 Contrast assessment revealed notable improvements with DDBMC. In continuous rotational motion, % contrast increased from 42.4% to 73.5%, In tilting motion, % contrast increased from 52.3% to 64.5%, eliminating significant differences from the static reference image. These findings underscore the efficacy of DDBMC in enhancing image contrast and minimizing motion induced variations across different motion scenarios.

conclusionsDDBMC processing can effectively compensate for continuous rotational and tilting motion of the head during PET, with motion angles of approximately 20 degrees. However, a significant limitation of this study is the exclusive validation of the proposed method using a Hoffman phantom; its applicability to the human brain has not been investigated. Further research involving human subjects is necessary to assess the generalizability and reliability of the presented motion correction technique in real clinical scenarios.

Indexed as

BrainImage Processing, Computer-AssistedPhantoms, ImagingArtifactsFluorodeoxyglucose F18HumansMotionPositron-Emission TomographyPositron Emission Tomography Computed TomographyFluorodeoxyglucose F18

Identifiers

PMID38968191
PMCPMC11226115

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.