ArticleTranslational vision science & technology2024
Viscoelastic, Optical, and Surgical Properties of Vitreous Body Replacement Hydrogels After Aging Compared to Porcine Vitreous Bodies And Silicone Oils.
Article in Translational vision science & technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Vitreous Substitutes in Vitreoretinal Surgery: From Native Vitreous Physiology to Bioengineered Experimental Replacements.Journal of functional biomaterials · 2026Review
- The effect of syringe design and cannula dimensions on time-force curve in intravitreal injection across different drug viscosities: area under the curve and peak injection force.International journal of retina and vitreous · 2026Article
- Clinical Management of Vision Degrading Myodesopsia from Vitreous Floaters: Observation vs. Limited Refractive Vitrectomy.Ophthalmology. Retina · 2025Article
- Replacing the vitreous body with hydrogels: Rationale and strategies.Progress in retinal and eye research · 2025Review
- Hydrogel-Based Vitreous Substitutes.International journal of molecular sciences · 2025Review
- F4H5 Alleviates Increased Outflow Resistance Induced by Emulsified Silicone Oil In Vitro.Investigative ophthalmology & visual science · 2025Article
- In Vitro Physicochemical and Pharmacokinetic Properties of Bevacizumab Dissolved in Silicone Oils Compared to Hydrogel-Substitutes and Porcine Vitreous Bodies.Gels (Basel, Switzerland) · 2024Article
- A review of human cornea finite element modeling: geometry modeling, constitutive modeling, and outlooks.Frontiers in bioengineering and biotechnology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: First- (monomers), second- (pre-gelated), and third- (in situ gelating after injection) generation hydrogels were previously introduced to replace the vitreous body after vitrectomy surgery. In this study, we evaluated the surgical, optical, and viscoelastic properties of vitreous body replacement hydrogels before and after an accelerated aging protocol previously applied to intraocular implants. Methods: Measurements of injection force, removal speed using a clinically established vitrectomy setup, as well as evaluation of forward light scattering and viscoelastic properties before and after an accelerated aging protocol were conducted. Results were compared to porcine and human vitreous bodies, as well as currently clinically applied lighter- and heavier-than-water silicone oils. Results: Removal speed of all tested hydrogels is substantially lower than the removal speed of porcine vitreous body (0.2 g/min vs. 2.7 g/min for the best performing hydrogel and porcine vitreous body, respectively). Forward light scattering in second-generation vitreous body replacement hydrogels was higher after the aging process than the straylight of the average 70-year-old vitreous body (9.4 vs. 5.5 deg2/sr, respectively). The viscoelastic properties of all hydrogels did not change in a clinically meaningful manner; however, trends toward greater stiffness and greater elasticity after aging were apparent. Conclusions: This study demonstrates surgical weaknesses of the hydrogels that need to be addressed before clinical use, especially low removal speed. Pre-linked hydrogels (second-generation) showed inferior performance regarding surgical properties compared to in situ gelating hydrogels (third-generation). Translational Relevance: This study highlights possible pitfalls regarding surgical and optical properties when applying vitreous replacement hydrogels clinically.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials