Fabrication and assessment of a bio-inspired synthetic tracheal tissue model for tracheal tube cuff leakage testing.

Tamaralayefa Agbiki, Richard Arm, David W Hewson, Sandor Erdody, Andrew M Norris, Ricardo Correia, Sergiy Korposh, Barrie R Hayes-Gill, Arash Shahidi, Stephen P Morgan

Abstract read
In one paragraph

Article in BJA open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Tamaralayefa AgbikiOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Richard ArmFlexural Composites Research Laboratory, Nottingham School of Art and Design, Nottingham Trent University, Nottingham, UK.
David W HewsonDepartment of Anaesthesia, Academic Unit of Injury, Recovery and Inflammation Sciences, School of Medicine, University of Nottingham, Nottingham, UK.
Sandor ErdodyOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Andrew M NorrisDepartment of Anaesthesiology, King Abdullah bin Abdulaziz University Hospital, Riyadh, Saudi Arabia.
Ricardo CorreiaOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Sergiy KorposhOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Barrie R Hayes-GillOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.
Arash ShahidiFlexural Composites Research Laboratory, Nottingham School of Art and Design, Nottingham Trent University, Nottingham, UK.
Stephen P MorganOptics and Photonics Research Group, Faculty of Engineering, University of Nottingham, Nottingham, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Leakage of orogastric secretions past the cuff of a tracheal tube is a contributory factor in ventilator-associated pneumonia. Current bench test methods specified in the International Standard for Anaesthetic and Respiratory Equipment (EN ISO 5361:2023) to test cuff leakage involve using a glass or plastic rigid cylinder model of the trachea. There is a need for more realistic models to inform cuff leakage. Methods: We used human computerised tomography data and additive manufacturing (3D printing), combined with casting techniques to fabricate a bio-inspired synthetic tracheal model with analogous tissue characteristics. We conducted cuff leakage tests according to EN ISO 5361:2023 and compared results for high-volume low-pressure polyvinyl chloride and polyurethane cuffs between the rigid cylinder trachea with our bio-inspired model. Results: The tracheal model demonstrated close agreement with published tracheal tissue hardness for cartilaginous and membranous soft tissues. For high-volume low-pressure polyvinyl chloride cuffs the leakage rate was >50% lower in the bio-inspired tracheal model compared with the rigid cylinder model (151 [8] Conclusion: A reproducible tracheal model that incorporates the mechanical properties of the human trachea can be manufactured from segmented CT images and additive manufactured moulds, providing a useful tool to inform future cuff development, leakage testing for industrial applications, and clinical decision-making. There are differences between cuff leakage rates between the bio-inspired model and the rigid cylinder recommended in EN ISO 5361:2023. The bio-inspired model could lead to more accurate and realistic cuff leakage rate testing which would support manufacturers in refining their designs. Clinicians would then be able to choose better tracheal tubes based on the outcomes of this testing.

Indexed as

cuff leakage testingsynthetic tissue modeltracheal tissue modeltracheal tubeventilator associated pneumonia

Identifiers

PMID38966590
PMCPMC11223077

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.