Evidence map›Paper›PMID 38964977›Full record

ArticleBrachytherapy

Dosimetric evaluation of a novel modular cell irradiation platform for multi-modality in vitro studies including high dose rate brachytherapy.

Aaron Silvus, Thomas R Mazur, S Murty Goddu, Ethan Memming, Jacqueline E Zoberi, Stephanie Markovina, Michael B Altman

Abstract readEvaluation Study
In one paragraph

Article in Brachytherapy. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Aaron SilvusDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO. Electronic address: a.k.silvus@wustl.edu.
Thomas R MazurDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO.
S Murty GodduDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO.
Ethan MemmingDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO.
Jacqueline E ZoberiDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO.
Stephanie MarkovinaDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO.
Michael B AltmanDepartment of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO.

Funding

Mechanisms of radiation-induced tumor cell death and survival in cervical cancerK08CA237822 · NCI · WASHINGTON UNIVERSITY · PI MARKOVINA, STEPHANIE · 2019 to 2023
$1.1M
NCI NIH HHS K08 CA237822
6 · The paper itself

Abstract

purposeHigh dose-rate (HDR) brachytherapy is integral for the treatment of numerous cancers. Preclinical studies involving HDR brachytherapy are limited. We aimed to describe a novel platform allowing multi-modality studies with clinical HDR brachytherapy and external beam irradiators, establish baseline dosimetry standard of a preclinical orthovoltage irradiator, to determine accurate dosimetric methods.

methodsA dosimetric assessment of a commercial preclinical irradiator was performed establishing the baseline dosimetry goals for clinical irradiators. A 3D printed platform was then constructed with 14 brachytherapy channels at 1cm spacing to accommodate a standard tissue culture plate at a source-to-cell distance (SCD) of 1 cm or 0.4 cm. 4-Gy CT-based treatment plans were created in clinical treatment planning software and delivered to 96-well tissue culture plates using an Ir192 source or a clinical linear accelerator. Standard calculation models for HDR brachytherapy and external beam were compared to corresponding deterministic model-based dose calculation algorithms (MBDCAs). Agreement between predicted and measured dose was assessed with 2D-gamma passing rates to determine the best planning methodology.

resultsMean (±standard deviation) and median dose measured across the plate for the preclinical irradiator was 423.7 ± 8.5 cGy and 430.0 cGy. Mean percentage differences between standard and MBDCA dose calculations were 9.4% (HDR, 1 cm SCD), 0.43% (HDR, 0.4 cm SCD), and 2.4% (EBRT). Predicted and measured dose agreement was highest for MBDCAs for all modalities.

conclusionA 3D-printed tissue culture platform can be used for multi-modality irradiation studies with great accuracy. This tool will facilitate preclinical studies to reveal biologic differences between clinically relevant radiation modalities.

Indexed as

BrachytherapyRadiometryRadiotherapy DosageAlgorithmsEquipment DesignHumansPrinting, Three-DimensionalRadiotherapy Planning, Computer-Assisted3D-printingFilm dosimetryHigh dose rate brachytherapyModel-based dose calculation algorithmsOrthovoltage irradiatorOSLD dosimetry

Identifiers

PMID38964977
PMCPMC12289239

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.