Evidence map›Paper›PMID 38964827›Full record

ArticleClinical & experimental ophthalmology2024

In-vivo high-frequency quantitative ultrasound-derived parameters of the anterior sclera correlated with level of myopia and presence of staphyloma.

Cameron Hoerig, Quan V Hoang, Jonathan Mamou

Abstract read
In one paragraph

Article in Clinical & experimental ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Cameron HoerigDepartment of Radiology, Weill Cornell Medicine, New York, New York, USA.ORCID 0000-0001-9107-095X
Quan V HoangSingapore Eye Research Institute, Singapore National Eye Centre, Duke-NUS, Singapore.
Jonathan MamouDepartment of Radiology, Weill Cornell Medicine, New York, New York, USA.

Funding

Novel in-vivo ultrasound-based point-of-care instrument to assess myopia level andprogressionR21EB028084 · NIBIB · WEILL MEDICAL COLL OF CORNELL UNIV · PI MAMOU, JONATHAN · 2020 to 2020
$430k
Lee Foundation TLF 0322-8Lee Foundation TLF1021-3National Medical Research Council MOH-000531-00National Medical Research Council MOH-001103-00NIBIB NIH HHS R21 EB028084NIBIB of the National Institutes of Health R21EB028084SERI-Lee Foundation LF0621-1SingHealth Foundation-SNEC R1499/82/2017
6 · The paper itself

Abstract

backgroundA high-frequency point-of-care (POC) ultrasound instrument was used to evaluate the microstructural and biomechanical properties of the anterior sclera in vivo using parameters computed from quantitative ultrasound (QUS) methods.

methodsIn this cross-sectional study, both eyes of 85 enrolled patients were scanned with the POC instrument and ultrasound data were processed to obtain QUS parameters. Pearson correlation and multi-linear regression were used to identify relationships between QUS parameters and refractive error (RE) or axial length. After categorising eyes based on RE, binary support vector machine (SVM) classifiers were trained using the QUS or ophthalmic parameters (anterior chamber depth, central corneal thickness, corneal power, and intraocular pressure) to classify each eye. Classifier performance was evaluated by computing the area under the receiver-operating characteristic curve (AUC).

resultsIndividual QUS parameters correlated with RE and axial length (p < 0.05). Multi-linear regression revealed significant correlation between the set of QUS parameters and both RE (R = 0.49, p < 0.001) and axial length (R = 0.46, p = 0.001). Classifiers trained with QUS parameters achieved higher AUC (𝑝 = 0.06) for identifying myopic eyes (AUC = 0.71) compared to classifiers trained with ophthalmic parameters (AUC = 0.63). QUS-based classifiers attained the highest AUC when identifying highly myopic eyes (AUC = 0.77).

conclusionsQUS parameters correlate with progressing myopia and may be indicative of myopia-induced microstructural and biomechanical changes in the anterior sclera. These methods may provide critical clinical information complementary to standard ophthalmic measurements for predicting myopia progression and risk assessment for posterior staphyloma formation.

Indexed as

Axial Length, EyeMyopiaROC CurveScleraScleral DiseasesUltrasonographyAdultAgedCross-Sectional StudiesDilatation, PathologicFemaleHumansIntraocular PressureMaleMiddle AgedPoint-of-Care Systemshigh‐frequency ultrasoundhigh myopiapassive elastographypathologic myopiaquantitative ultrasound

Identifiers

PMID38964827
PMCPMC11560725

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.