ArticleHeliyon2024
Three-dimensional finite element analysis of the biomechanical behaviour of different dental implants under immediate loading during three masticatory cycles.
Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Biomechanical Effects of Implant-Root Fragment Contact in the Socket Shield Technique: A Finite Element Analysis.International dental journal · 2026Article
- Biomechanical effects of different carbon fiber-reinforced polyetheretherketone dental implants materials in edentulous maxilla: A 3D finite element study.BMC oral health · 2026Article
- Finite Element Analysis of Peri-Implant Stress in Maxillary All-on-Four Rehabilitation: Effects of Posterior Implant Angulation and Loading Protocol.Materials (Basel, Switzerland) · 2026Article
- Article
- Stress Assessment of Abutment-Free and Three Implant-Abutment Connections Utilizing Various Abutment Materials: A 3D Finite Element Study of Static and Cyclic Static Loading Conditions.Journal of functional biomaterials · 2025Article
- The impact of physiological and parafunctional posterior occlusal forces on experimental Ti-15Zrsupracrestal dental implant - a finite element analysis.Medicine and pharmacy reports · 2025Article
- CF-PEEK vs. Titanium Dental Implants: Stress Distribution and Fatigue Performance in Variable Bone Qualities.Biomimetics (Basel, Switzerland) · 2025Article
- Comparative analysis of occlusal stresses on bone around natural teeth, platform matched and switched implants abutments: a finite element study.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The study aimed to evaluate the impact of varying modulus of elasticity (MOE) values of dental implants on the deformation and von Mises stress distribution in implant systems and peri-implant bone tissues under dynamic cyclic loading. The implant-bone interface was characterised as frictional contact, and the initial stress was induced using the interference fit method to effectively develop a finite element model for an immediately loaded implant-supported denture. Using the Ansys Workbench 2021 R2 software, an analysis was conducted to examine the deformation and von Mises stress experienced by the implant-supported dentures, peri-implant bone tissue, and implants under dynamic loading across three simulated masticatory cycles. These findings were subsequently evaluated through a comparative analysis. The suprastructures showed varying degrees of maximum deformation across zirconia (Zr), titanium (Ti), low-MOE-Ti, and polyetheretherketone (PEEK) implant systems, registering values of 103.1 μm, 125.68 μm, 169.52 μm, and 844.06 μm, respectively. The Zr implant system demonstrated the lowest values for both maximum deformation and von Mises stress (14.96 μm, 86.71 MPa) in cortical bone. As the MOE increased, the maximum deformation in cancellous bone decreased. The PEEK implant system exhibited the highest maximum von Mises stress (59.12 MPa), whereas the Ti implant system exhibited the lowest stress (22.48 MPa). Elevating the MOE resulted in reductions in both maximum deformation and maximum von Mises stress experienced by the implant. Based on this research, adjusting the MOE of the implant emerged as a viable approach to effectively modify the biomechanical characteristics of the implant system. The Zr implant system demonstrated the least maximum von Mises stress and deformation, presenting a more favourable quality for preserving the stability of the implant-bone interface under immediate loading.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials