Evidence map›Paper›PMID 38959266›Full record

ArticlePloS one2024

Electric field and SAR reduction in high-impedance RF arrays by using high permittivity materials for 7T MR imaging.

Aditya A Bhosale, Yunkun Zhao, Xiaoliang Zhang

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Aditya A BhosaleDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States of America.ORCID 0000-0002-2796-1472
Yunkun ZhaoDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States of America.ORCID 0009-0006-2859-4500
Xiaoliang ZhangDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States of America.ORCID 0000-0001-9599-595X

Funding

Enhanced MR for morphological characterization of ligaments, tendons and boneU01EB023829 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LI, XIAOJUAN, ZHANG, XIAOLIANG · 2018 to 2024
$1.9M
NIBIB NIH HHS U01 EB023829
6 · The paper itself

Abstract

In the field of ultra-high field MR imaging, the challenges associated with higher frequencies and shorter wavelengths necessitate rigorous attention to multichannel array design. While the need for such arrays remains, and efforts to increase channel counts continue, a persistent impediment-inter-element coupling-constantly hinders development. This coupling degrades current and field distribution, introduces noise correlation between channels, and alters the frequency of array elements, affecting image quality and overall performance. The goal of optimizing ultra-high field MRI goes beyond resolving inter-element coupling and includes significant safety considerations related to the design changes required to achieve high-impedance coils. Although these coils provide excellent isolation, the higher impedance needs special design changes. However, such changes pose a significant safety risk in the form of strong electric fields across low-capacitance lumped components. This process may raise Specific Absorption Rate (SAR) values in the imaging subject, increasing power deposition and, as a result, the risk of tissue heating-related injury. To balance the requirement of inter-element decoupling with the critical need for safety, we suggest a new solution. Our method uses high-dielectric materials to efficiently reduce electric fields and SAR values in the imaging sample. This intervention tries to maintain B1 efficiency and inter-element decoupling within the existing array design, which includes high-impedance coils. Our method aims to promote the full potential of ultra-high field MRI by alleviating this critical safety concern with minimal changes to the existing array setup.

Indexed as

Electric ImpedanceMagnetic Resonance ImagingEquipment DesignHumansPhantoms, ImagingRadio Waves

Identifiers

PMID38959266
PMCPMC11221758

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.