Evidence map›Paper›PMID 38957291›Full record

ArticleThe journal of advanced prosthodontics2024

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts.

Anne Kaline Claudino Ribeiro, Aretha Heitor Veríssimo, Rodrigo Falcão Carvalho Porto de Freitas, Rayanna Thayse Florêncio Costa, Burak Yilmaz, Sandra Lúcia Dantas de Moraes, Adriana da Fonte Porto Carreiro

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Anne Kaline Claudino RibeiroDepartment of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.ORCID https://orcid.org/0000-0001-7839-1476
Aretha Heitor VeríssimoDepartment of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.ORCID https://orcid.org/0000-0002-7951-8843
Rodrigo Falcão Carvalho Porto de FreitasDepartment of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.ORCID https://orcid.org/0000-0002-0597-8329
Rayanna Thayse Florêncio CostaDepartment of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Pernambuco, Brazil.ORCID https://orcid.org/0000-0002-5336-8007
Burak YilmazDepartment of Gerodontology and Reconstructive Dentistry, University of Bern, School of Dentistry, Bern, Switzerland.ORCID https://orcid.org/0000-0002-7101-363X
Sandra Lúcia Dantas de MoraesDepartment of Oral Rehabilitation, Faculty of Dentistry, University of Pernambuco (UPE), Recife, Pernambuco, Brazil.ORCID https://orcid.org/0000-0002-3154-5092
Adriana da Fonte Porto CarreiroDepartment of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.ORCID https://orcid.org/0000-0002-0833-1926

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND

methodsA total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time.

resultsThe accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (

conclusionThe denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

Indexed as

AccuracyComplete dentureComputer-aided designDenture foundationEdentulous mouth

Identifiers

PMID38957291
PMCPMC11215037

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.