Evidence map›Paper›PMID 38956625›Full record

ArticleBMC oral health2024

Effectiveness of different intrusion modes of maxillary anterior teeth with mini-implants in clear aligner treatment: a three-dimensional finite element analysis.

Tian Xiao, Jing-Yuan Su, Jie Lei, Xin Zhang, Jian Yu, Xiu-Ping Nie, Qiao-Hui Ying, Jun-Xiang Hou, Jie Guo

Abstract read
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tian XiaoDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Jing-Yuan SuDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Jie LeiDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Xin ZhangDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Jian YuDepartment of Radiology, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Xiu-Ping NieDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Qiao-Hui YingDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China.
Jun-Xiang HouR&D center, Wuxi EA Medical Instruments Technologies Ltd, Wuxi, 214174, China.
Jie GuoDepartment of Orthodontics, School and Hospital of Stomatology, Cheeloo College of Medicine, Shandong Key Laboratory of Oral Tissue Regeneration & Shandong Engineering Research Center of Dental Materials and Oral Tissue Regeneration & Shandong Provincial Clinical Research Center for Oral Diseases, Shandong University, No.44-1 Wenhua Road West, Jinan, Shandong, 250012, China. kqgjsdu@163.com.

Funding

Horizontal Project of Shandong University 1350022008National Natural Science Foundation of China 81970964
6 · The paper itself

Abstract

backgroundThe intrusion of maxillary anterior teeth is often required and there are various intrusion modes with mini-implants in clear aligner treatment. The objective of this study was to evaluate the effectiveness of maxillary anterior teeth intrusion with different intrusion modes, aiming to provide references for precise and safe intrusion movements in clinical practice.

methodsCone-beam computed tomography and intraoral optical scanning data of a patient were collected. Finite element models of the maxilla, maxillary dentition, periodontal ligaments (PDLs), clear aligner (CA), attachments, and mini-implants were established. Different intrusion modes of the maxillary anterior teeth were simulated by changing the mini-implant site (between central incisors, between central and lateral incisor, between lateral incisor and canine), loading site (between central incisors, on central incisor, between central and lateral incisor, between lateral incisor and canine), and loading mode (labial loading and labiolingual loading). Ten conditions were generated and intrusive forces of 100 g were applied totally. Then displacement tendency of the maxillary anterior teeth and CA, and stress of the PDLs were analyzed.

resultsFor the central incisor under condition L14 and for the canine under conditions L11, L13, L23, and L33, the intrusion amount was negative. Under other conditions, the intrusion amount was positive. The labiolingual angulation of maxillary anterior teeth exhibited positive changes under all conditions, with greater changes under linguoincisal loading. The mesiodistal angulation of canine exhibited positive changes under labial loading, while negative changes under linguoincisal loading except for condition L14.

conclusionsThe intrusion amount, labiolingual and mesiodistal angulations of the maxillary anterior teeth were affected by the mini-implant site, loading site, and loading mode. Labial and linguoincisal loading may have opposite effects on the intrusion amount of maxillary anterior teeth and the mesiodistal angulation of canine. The labiolingual angulation of the maxillary incisors would increase under all intrusion modes, with greater increases under linguoincisal loading.

Indexed as

Cone-Beam Computed TomographyDental ImplantsFinite Element AnalysisIncisorMaxillaOrthodontic Anchorage ProceduresPeriodontal LigamentTooth Movement TechniquesBiomechanical PhenomenaCuspidDental Stress AnalysisHumansImaging, Three-DimensionalOrthodontic Appliance DesignOrthodontic Appliances, RemovableDental ImplantsClear alignerFinite element analysisIntrusion modesMini-implant

Identifiers

PMID38956625
PMCPMC11218253

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.