Evidence map›Paper›PMID 38955890›Full record

ArticleAnnals of biomedical engineering2024

Instrumented Mouthguard Decoupling Affects Measured Head Kinematic Accuracy.

Ryan A Gellner, Mark T Begonia, Matthew Wood, Lewis Rockwell, Taylor Geiman, Caitlyn Jung, Steve Rowson

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ryan A GellnerVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA. gryan3@vt.edu.ORCID http://orcid.org/0000-0001-7092-2527
Mark T BegoniaVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Matthew WoodVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Lewis RockwellVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Taylor GeimanVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Caitlyn JungVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Steve RowsonVirginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many recent studies have used boil-and-bite style instrumented mouthguards to measure head kinematics during impact in sports. Instrumented mouthguards promise greater accuracy than their predecessors because of their superior ability to couple directly to the skull. These mouthguards have been validated in the lab and on the field, but little is known about the effects of decoupling during impact. Decoupling can occur for various reasons, such as poor initial fit, wear-and-tear, or excessive impact forces. To understand how decoupling influences measured kinematic error, we fit a boil-and-bite instrumented mouthguard to a 3D-printed dentition mounted to a National Operating Committee on Standards for Athletic Equipment (NOCSAE) headform. We also instrumented the headform with linear accelerometers and angular rate sensors at its center of gravity (CG). We performed a series of pendulum impact tests, varying impactor face and impact direction. We measured linear acceleration and angular velocity, and we calculated angular acceleration from the mouthguard and the headform CG. We created decoupling conditions by varying the gap between the lower jaw and the bottom face of the mouthguard. We tested three gap conditions: 0 mm (control), 1.6 mm, and 4.8 mm. Mouthguard measurements were transformed to the CG and compared to the reference measurements. We found that gap condition, impact duration, and impact direction significantly influenced mouthguard measurement error. Error was higher for larger gaps and in frontal (front and front boss) conditions. Higher errors were also found in padded conditions, but the mouthguards did not collect all rigid impacts due to inherent limitations. We present characteristic decoupling time history curves for each kinematic measurement. Exemplary frequency spectra indicating characteristic decoupling frequencies are also described. Researchers using boil-and-bite instrumented mouthguards should be aware of their limitations when interpreting results and should seek to address decoupling through advanced post-processing techniques when possible.

Indexed as

HeadMouth ProtectorsBiomechanical PhenomenaEquipment DesignHumansSports EquipmentBoil-and-biteDecouplingHeadImpactInstrumented mouthguardKinematicsMeasurement error

Identifiers

PMID38955890
PMCPMC11402849

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.