Evidence map›Paper›PMID 38955816›Full record

ArticleCardiovascular and interventional radiology2024

Safety and Performance of a Cell-Impermeable Endoprosthesis for Hemodialysis Vascular Access Outflow Stenosis: A Brazilian Multicenter Retrospective Study.

Leonardo de Oliveira Harduin, Thiago Almeida Barroso, Julia Bandeira Guerra, Márcio Gomes Filippo, Leonardo Cortizo de Almeida, Brunno Ribeiro Vieira, Renata Silveira Mello, Adriano Martins Galhardo, Jorge Paulo Strogoff-de-Matos

Abstract readMulticenter Study
In one paragraph

Article in Cardiovascular and interventional radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Leonardo de Oliveira HarduinLiv Care Centro Clínico, Niterói, Rio de Janeiro, 24220-002, Brazil. leonardoharduin@yahoo.com.br.ORCID http://orcid.org/0000-0001-9012-9649
Thiago Almeida BarrosoAfya Hospital Dia, Brasília, Distrito Federal, Brazil.
Julia Bandeira GuerraImage Department, Hospital Niterói Dor and Centro Clínico LIVCARE, Niterói, Rio de Janeiro, Brazil.
Márcio Gomes FilippoVascular Surgery Service, Hospital Universitário Clementino Fraga Filho (HUCFF), Universidade Federal do Estado do Rio de Janeiro (UFRJ), Rio de Janeiro, Rio de Janeiro, Brazil.
Leonardo Cortizo de AlmeidaVascular Surgery Service, Hospital Ana Nery, Salvador, Bahia, Brazil.
Brunno Ribeiro VieiraInstituto Nacional de Traumatologia e Ortopedia, Rio de Janeiro, Rio de Janeiro, Brazil.
Renata Silveira MelloVascular Surgery Service, Hospital Niterói Dor, Niterói, Rio de Janeiro, Brazil.
Adriano Martins GalhardoAfya Hospital Dia, Brasília, Distrito Federal, Brazil.
Jorge Paulo Strogoff-de-MatosDivisão de Nefrologia, Departamento de Medicina, Faculdade de Medicina, Universidade Federal Fluminense, Niterói, Rio de Janeiro, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the safety and performance of Wrapsody™, a cell-impermeable endoprosthesis (CIE), for treating hemodialysis vascular access outflow stenosis. MATERIALS AND

methodsInvestigators retrospectively analyzed 113 hemodialysis patients treated with a CIE (11/2021-12/2022) across four centers in Brazil. De novo or restenotic lesions were treated. The primary efficacy outcome measure was target lesion primary patency (TLPP) at 1, 3, 6, and 12 months; the primary safety outcome measure was the absence of serious local or systemic adverse events within the first 30 days post-procedure. Secondary outcome measures included technical and procedural success, access circuit primary patency (ACPP), and secondary patency at 1, 3, 6, and 12 months post-procedure.

resultsThirty-nine patients (34.5%) had thrombosed access at the initial presentation, and 38 patients (33.6%) presented with recurrent stenosis. TLPP rates at 1, 3, 6, and 12 months were 100%, 96.4%, 86.4%, and 69.7%, respectively. ACPP rates were 100% at 1 month, 89.2% at 3 months, 70.9% at 6 months, and 56.0% at 12 months. The target lesion secondary patency rates at 1, 3, 6, and 12 months were 100%, 97.3%, 93.6%, and 91.7%, respectively. In the adjusted multivariate Cox regression analysis, male sex and endoprosthesis with diameters of 10, 12, 14, and 16 mm were associated with improved primary patency rates. No localized or systemic serious adverse event was observed through the first 30 days post-procedure.

conclusionThe CIE evaluated in this study is safe and effective for treating peripheral and central outflow stenoses in hemodialysis vascular access. LEVEL OF EVIDENCE: Level 2b, cohort study.

Indexed as

Graft Occlusion, VascularRenal DialysisVascular PatencyAdultAgedArteriovenous Shunt, SurgicalBlood Vessel ProsthesisBrazilConstriction, PathologicFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeCell-impermeable endoprosthesisCovered stentHemodialysisStenosisStent graftVascular access

Identifiers

PMID38955816
PMCPMC11303476

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.