Evidence map›Paper›PMID 38952746›Full record

ArticleFrontiers in digital health2024

Energy expenditure estimation during activities of daily living in middle-aged and older adults using an accelerometer integrated into a hearing aid.

Jan Stutz, Philipp A Eichenberger, Nina Stumpf, Samuel E J Knobel, Nicholas C Herbert, Isabel Hirzel, Sacha Huber, Chiara Oetiker, Emily Urry, Olivier Lambercy and 1 more

Abstract read
In one paragraph

Article in Frontiers in digital health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jan StutzExercise Physiology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
Philipp A EichenbergerExercise Physiology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
Nina StumpfResearch & Development, Sonova AG, Stäfa, Switzerland.
Samuel E J KnobelResearch & Development, Sonova AG, Stäfa, Switzerland.
Nicholas C HerbertResearch & Development, Sonova AG, Stäfa, Switzerland.
Isabel HirzelExercise Physiology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
Sacha HuberExercise Physiology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
Chiara OetikerExercise Physiology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
Emily UrryResearch & Development, Sonova AG, Stäfa, Switzerland.
Olivier LambercyRehabilitation Engineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.
Christina M SpenglerExercise Physiology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accelerometers were traditionally worn on the hip to estimate energy expenditure (EE) during physical activity but are increasingly replaced by products worn on the wrist to enhance wear compliance, despite potential compromises in EE estimation accuracy. In the older population, where the prevalence of hearing loss is higher, a new, integrated option may arise. Thus, this study aimed to investigate the accuracy and precision of EE estimates using an accelerometer integrated into a hearing aid and compare its performance with sensors simultaneously worn on the wrist and hip. Methods: Sixty middle-aged to older adults (average age 64.0 ± 8.0 years, 48% female) participated. They performed a 20-min resting energy expenditure measurement (after overnight fast) followed by a standardized breakfast and 13 different activities of daily living, 12 of them were individually selected from a set of 35 activities, ranging from sedentary and low intensity to more dynamic and physically demanding activities. Using indirect calorimetry as a reference for the metabolic equivalent of task (MET), we compared the EE estimations made using a hearing aid integrated device (Audéo) against those of a research device worn on the hip (ZurichMove) and consumer devices positioned on the wrist (Garmin and Fitbit). Class-estimated and class-known models were used to evaluate the accuracy and precision of EE estimates via Bland-Altman analyses. Results: The findings reveal a mean bias and 95% limit of agreement for Audéo (class-estimated model) of -0.23 ± 3.33 METs, indicating a slight advantage over wrist-worn consumer devices (Garmin: -0.64 ± 3.53 METs and Fitbit: -0.67 ± 3.40 METs). Class-know models reveal a comparable performance between Audéo (-0.21 ± 2.51 METs) and ZurichMove (-0.13 ± 2.49 METs). Sub-analyses show substantial variability in accuracy for different activities and good accuracy when activities are averaged over a typical day's usage of 10 h (+61 ± 302 kcal). Discussion: This study shows the potential of hearing aid-integrated accelerometers in accurately estimating EE across a wide range of activities in the target demographic, while also highlighting the necessity for ongoing optimization efforts considering precision limitations observed across both consumer and research devices.

Indexed as

AudéocaloriesearableelderlyFitbitGarminmetabolism

Identifiers

PMID38952746
PMCPMC11215182

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.