Evidence map›Paper›PMID 38952523›Full record

ArticlePakistan journal of medical sciences2024

A resonance frequency analysis to investigate the impact of implant size on primary and secondary stability.

Mahvish Wahad Khan, Naveed Inayat, Muhammad Sohail Zafar, Abdul Mueed Zaigham

Abstract read
In one paragraph

Article in Pakistan journal of medical sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mahvish Wahad KhanMahvish Wahad Khan, BDS, FCPS Assistant Professor, Department of Prosthodontics Avicenna Medical & Dental College, Phase IX, DHA, Bedian Road, Lahore, Pakistan.
Naveed InayatNaveed Inayat, BDS, FCPS, FICD Associate Professor, Department of Prosthodontics Azra Naheed Dental College, Superior University, Lahore, Pakistan.
Muhammad Sohail ZafarProf. Muhammad Sohail Zafar, BDS, M.Sc, PhD Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madina, Al Munawwarra 41311, Saudi Arabia. Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad 44000, Pakistan.
Abdul Mueed ZaighamProf. Abdul Mueed Zaigham, BDS, FCPS Department of Prosthodontics, Institute of Dentistry, CMH Lahore Medical College, Abdur Rehman Road, Lahore. National University of Medical Sciences, Rawalpindi, Pakistan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Recent years have seen a rise in the usage of dental implants to restore lost teeth. The stability of a dental implant is the main factor in determining its success. Implant stability is influenced by various factors. Several approaches have been employed clinically to evaluate stability at different time intervals. One non-invasive way to assess implant stability is by resonance frequency analysis. Utilizing the resonance frequency analysis method, this study seeks to understand how implant length and diameter affect primary and secondary stability. Methods: The current prospective study was conducted in the Prosthodontics Department of Institute of Dentistry, CMH Lahore Medical College. The duration of the study was six months. A total of 90 implants of sizes 4.5 x 8.5 mm and 4 x 10mm were placed. Resonance frequency measurements were recorded using Osstell™ AB device for primary stability at implant insertion and at 12 weeks for secondary stability. All the measurements were carried out by only one of the researchers to minimize inter-observer bias. Results: The average primary stability was 70.33±6.60, and the average secondary stability was 71.43±5.44. The data was stratified for age, gender, and implant site, and the mean primary and secondary stability of both sizes didn't show any statistically significant differences. Conclusion: Without forfeiting implant stability, both implant sizes (4 x 10mm and 4.5 x 8.5mm) can be used interchangeably, depending on available space and anatomical constraints.

Indexed as

Implant stabilityImplant stability quotient (ISQ)Primary stabilityResonance frequencySecondary stability

Identifiers

PMID38952523
PMCPMC11190384

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.